2020
DOI: 10.1111/clr.13597
|View full text |Cite
|
Sign up to set email alerts
|

Stability of screw‐retention in two‐piece zirconia implants: An in vitro study

Abstract: ObjectivesTo compare the stability of a screw‐retained connection in a novel two‐piece zirconia implant to a conventional titanium‐based connection in an in vitro chewing simulation including artificial ageing.Material and methodsIncisor (I) and molar (M) shaped monolithic zirconia crowns were screw‐retained on either two‐piece zirconia (test) or two‐piece titanium (control) implants resulting in 4 groups of 8 samples (titanium implants with incisor‐shaped crowns (T‐I), titanium implants with molar‐shaped crow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
23
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(24 citation statements)
references
References 36 publications
0
23
1
Order By: Relevance
“…Dynamic loading and accelerated aging tests are a reliable method to provide essential information on limitations and lifetime predictions of ceramic restorations [ 29 ]. The applied fatigue protocol with 1.2 million cycles and simultaneous thermocycling corresponds to a clinical exposure time of 5 years and is a well-accepted method [ 27 , 28 , 30 , 31 , 32 ]. In the present study, all specimens survived exposure to an artificial oral environment with thermomechanical loading.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Dynamic loading and accelerated aging tests are a reliable method to provide essential information on limitations and lifetime predictions of ceramic restorations [ 29 ]. The applied fatigue protocol with 1.2 million cycles and simultaneous thermocycling corresponds to a clinical exposure time of 5 years and is a well-accepted method [ 27 , 28 , 30 , 31 , 32 ]. In the present study, all specimens survived exposure to an artificial oral environment with thermomechanical loading.…”
Section: Discussionmentioning
confidence: 99%
“…In vitro studies reported loading capacities for 3Y-TZP monolithic zirconia crowns (Vita YZ T) above 6000 N [ 30 ] on one-piece zirconia implants from the same manufacturer (vitaclinical) and between 4700 and 6350 N for 3Y-TZP monolithic implant crowns (Lava Plus) on one-piece zirconia implants (PURE Ceramic Implant, Straumann) [ 31 ] and 6310 N for 3Y-TZP monolithic zirconia crowns (Zerion LT) on two-piece zirconia implants (PURE two-piece implant, Straumann) [ 32 ]. Identical fatigue protocols simulating 5 years of clinical service was applied in the aforementioned studies to further stress the restorative-implant complex [ 30 , 31 , 32 ]. Different ranges in failure loads can be explained by different implant diameters (4.1 mm), two-piece design [ 32 ], abutment height (4.0 mm) [ 31 ] and choice of adhesive cements [ 30 ], as well as the crown design itself.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although long‐term results for zirconia implants are still missing and elevated heat generation was reported in vitro during implant insertion with zirconia implants when compared to titanium implants (Zipprich et al., 2019), promising clinical data investigating the outcome of one‐piece zirconia implants after an observation period of 5 years have been recently obtained (Balmer et al., 2020). Newly developed two‐piece zirconia implants, which are supposed to overcome problems caused by challenging abutment angulations (Wenz et al., 2008), showed a similar screw‐retained stability in vitro (artificial ageing process) when compared to a conventional titanium‐based connection (Joos et al., 2020).…”
Section: Introductionmentioning
confidence: 99%
“…In most clinically commercialized zirconia implant systems, one-piece implants are preferred over two-piece ones. 13 14 In some studies, one-piece zirconia implants showed good tissue response and a satisfactory degree of biocompatibility. 15 16 17 In 3-year follow-up studies on the success and survival of one-piece zirconia implants, survival rates ranged from 97.5% to 98.5%, which are almost identical to those of titanium implants.…”
Section: Introductionmentioning
confidence: 99%