2008
DOI: 10.1177/039463200802100206
|View full text |Cite
|
Sign up to set email alerts
|

Stability of Sirolimus and Everolimus Measured by Immunoassay Techniques in Whole Blood Samples from Kidney Transplant Patients

Abstract: The measurement of blood concentration of immunosuppressive drugs is strongly recommended because of the narrow therapeutic range. An important aspect in the therapeutic monitoring of a drug is its possible degradation. This paper is aimed at investigating the stability of two widely-used immunosuppressants, sirolimus and everolimus. Short (storage at 30 degrees C for 3 or 7 days) and long term (storage at -20 degrees C for 0-90 days with a single freeze-thaw cycle) stability of sirolimus and everolimus in who… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…Blood samples were frozen at −80°C for 1 month prior to analysis, which might have adversely affected measurement of the rapamycin concentration in those samples. Results of other studies 24,25 indicate that the rapamycin concentration is not substantially affected in blood samples stored frozen at −80°C for 90 days and subsequently thawed. Therefore, we do not believe that blood sample storage prior to analysis significantly affected measurement of blood rapamycin concentration in the present study.…”
Section: Discussionmentioning
confidence: 79%
“…Blood samples were frozen at −80°C for 1 month prior to analysis, which might have adversely affected measurement of the rapamycin concentration in those samples. Results of other studies 24,25 indicate that the rapamycin concentration is not substantially affected in blood samples stored frozen at −80°C for 90 days and subsequently thawed. Therefore, we do not believe that blood sample storage prior to analysis significantly affected measurement of blood rapamycin concentration in the present study.…”
Section: Discussionmentioning
confidence: 79%
“…Transport of the sample is performed after immediate freezing post-sampling (<4 h). 13 Because these pre-analytical recommendations were followed for this patient, an analytical error was not suspected.…”
Section: Discussionmentioning
confidence: 99%
“…The Yukon Choice PC – Elite Coronary Stent System is a balloon-expandable sirolimus-eluting coronary stent with a micro porous surface and a fully biodegradable abluminal polymer, mounted on a low-profile rapid-exchange delivery system provided in a temperature-controlled packaging. 10 …”
Section: Methodsmentioning
confidence: 99%