2015
DOI: 10.1007/s10762-015-0212-2
|View full text |Cite
|
Sign up to set email alerts
|

Stabilization of Gyrotron Frequency by PID Feedback Control on the Acceleration Voltage

Abstract: The results of frequency stabilization by proportional-integral-derivative (PID) feedback control of acceleration voltage in the 460-GHz Gyrotron FU CW GVI (the official name in Osaka University is Gyrotron FU CW GOI) are presented. The experiment was organized on the basis of the frequency modulation by modulation of acceleration voltage of beam electrons. The frequency stabilization during 10 h experiment was better than 10 −6 , which is compared with the results of the frequency deviation in free-running gy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(4 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…In paper [83], the authors report the frequency stability of the free-running gyrotron ≈ 10 MHz. After applying PID stabilization, 10 hours of operation revealed a frequency deviation of 0.6 MHz.…”
Section: Cathode Voltage Control -Frequency Stabilizationmentioning
confidence: 99%
“…In paper [83], the authors report the frequency stability of the free-running gyrotron ≈ 10 MHz. After applying PID stabilization, 10 hours of operation revealed a frequency deviation of 0.6 MHz.…”
Section: Cathode Voltage Control -Frequency Stabilizationmentioning
confidence: 99%
“…In the subsequent studies, the technique of the output parameters stabilization based on PID control has been mastered, and now it is routinely used in the gyrotrons for DNP-NMR spectroscopy [45,46]. It allows stabilizing the output power and frequency separately [47] as well as simultaneously [48], although in the latter case, the levels of the stabilizations are lower. Nevertheless, however, such a trade-off provides sufficiently stable radiation for the mentioned spectroscopic experiments.…”
Section: Characteristic Features Of the Gyrotrons And Their Radiationmentioning
confidence: 99%
“…Nevertheless, however, such a trade-off provides sufficiently stable radiation for the mentioned spectroscopic experiments. Generally, what is nowadays typical for the DNP-NMR gyrotrons is a long-term frequency stabilization with 0.2-0.4 MHz frequency spectrum width (stabilization is better than 10 −6 ) [47].…”
Section: Characteristic Features Of the Gyrotrons And Their Radiationmentioning
confidence: 99%
“…A proportional-integral-derivative (PID) feedback control system has been developed, which decreases the beam current fluctuations from 17 % to 0.5% and these of the output power from 15 % to 5 % by controlling the current of the heating filament of the cathode. More effective stabilization of the output power (up to 2%) has been realized by a feedback control that adjusts the voltage of the heater [37][38][39].…”
Section: Dnp-nmr Spectroscopymentioning
confidence: 99%