1996
DOI: 10.1016/0300-9440(95)00587-0
|View full text |Cite
|
Sign up to set email alerts
|

Stabilization of the polymer-metal interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
20
0
2

Year Published

2005
2005
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(23 citation statements)
references
References 2 publications
1
20
0
2
Order By: Relevance
“…[13,33,34] The value of isoelectrical point of the oxide and the hydroxylated aluminium oxide on the surface of aluminium sheet is about 9-9.2. [33,34] So, the aluminium oxide and the hydroxylated aluminium oxide on aluminium surface will be positively charged when dipping the aluminium sheets into the γ -APS aqueous solution in ethanol. According to the mechanism of acid and base interactions, the negatively charged silanol groups will interact with the positively charged aluminium oxide and hydroxylated aluminium oxide.…”
Section: Xps Of Interphases and Interfacial Interactionsmentioning
confidence: 99%
“…[13,33,34] The value of isoelectrical point of the oxide and the hydroxylated aluminium oxide on the surface of aluminium sheet is about 9-9.2. [33,34] So, the aluminium oxide and the hydroxylated aluminium oxide on aluminium surface will be positively charged when dipping the aluminium sheets into the γ -APS aqueous solution in ethanol. According to the mechanism of acid and base interactions, the negatively charged silanol groups will interact with the positively charged aluminium oxide and hydroxylated aluminium oxide.…”
Section: Xps Of Interphases and Interfacial Interactionsmentioning
confidence: 99%
“…Chemical (adhesion) bonds can be detected with different methods [6,7]. According to [8], the adhesive interaction in the presence of water is determined by the isoelectric point of a hydroxylated oxidized metal surface ( pH IEPS ) and the acid dissociation constant ( p K α ) of a polymer's polar group.…”
Section: Introductionmentioning
confidence: 99%
“…For the coating containing IBA-Fe 3 O 4 , the wet adherence improvement can be also attributed to the IBA release in the presence of water, which reacted with iron oxides at the steel surface. 36 From the cross-cut test, it was not possible to discriminate between the adherences of the three systems at the initial state (as-prepared samples). Thus, the three-point bending test was performed to better characterize the interfacial phenomena (the failure initiation is well defined in this test) at the initial state (i.e., before aging).…”
Section: Adherence Measurementsmentioning
confidence: 99%