In this study, we extended a previously developed one-pot double derivatization reaction to establish the first routine isotope-coded multiplex derivatization for vitamin D and its metabolites for application in clinical environments, using commercial reagents, without the need for specialized reagents and advanced synthesis requirements. The original derivatization process consisted of using both a Cookson-type reagent and derivatization of hydroxyl groups. Initially, the analytes are derivatized by a Diels−Alder reaction using 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD), followed by acetylation using acetic anhydride, catalyzed by 4-dimethylaminopyridine at room temperature. To enable sample multiplexing, we utilized acetic anhydride as well as the d 3isotopologue of acetic anhydride, generating d 3 -and d 6 -products of the investigated vitamin D 3 metabolites. This approach not only allowed for the simultaneous measurement of two samples within a single LC-MS/MS run but also improved the LC separation of the important 25-hydroxyvitamin D 3 epimers (3α-25(OH)D 3 and 3β-25(OH)D 3 ) on a conventional C-18 column, addressing a significant challenge in vitamin D analysis. Typically, the separation of these epimers after PTAD derivatization cannot be performed on C-18 columns, necessitating the use of pentafluorophenylpropyl (PFP) stationary phases. However, PFP columns are not as stable as C-18 in long-term use, wherein the acetylation of the C-3 hydroxyl group provided a solution by enhancing chromatographic selectivity and achieving the baseline separation of the metabolites 24,25(OH) 2 D 3 , 3α-25(OH)D 3 , 3β-25(OH)D 3 , and vitamin D 3 using a C-18 column with methanol/water gradient elution. The described duplex derivatization was tested on 40 serum samples of patients with chronic liver diseases (CLD). Additionally, the method was evaluated in terms of linearity, accuracy, precision, and interferences between heavy and light tag samples using both commercial quality control samples and in-house quality control and calibration samples.
In this study, we extended a previously developed one-pot double derivatization reaction to establish the first routine isotope-coded multiplex derivatization for vitamin D and its metabolites for application in clinical environments, using commercial reagents, without the need for specialized reagents and advanced synthesis requirements. The original derivatization process consisted of using both a Cookson-type reagent and derivatization of hydroxyl groups. Initially, the analytes are derivatized by a Diels−Alder reaction using 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD), followed by acetylation using acetic anhydride, catalyzed by 4-dimethylaminopyridine at room temperature. To enable sample multiplexing, we utilized acetic anhydride as well as the d 3isotopologue of acetic anhydride, generating d 3 -and d 6 -products of the investigated vitamin D 3 metabolites. This approach not only allowed for the simultaneous measurement of two samples within a single LC-MS/MS run but also improved the LC separation of the important 25-hydroxyvitamin D 3 epimers (3α-25(OH)D 3 and 3β-25(OH)D 3 ) on a conventional C-18 column, addressing a significant challenge in vitamin D analysis. Typically, the separation of these epimers after PTAD derivatization cannot be performed on C-18 columns, necessitating the use of pentafluorophenylpropyl (PFP) stationary phases. However, PFP columns are not as stable as C-18 in long-term use, wherein the acetylation of the C-3 hydroxyl group provided a solution by enhancing chromatographic selectivity and achieving the baseline separation of the metabolites 24,25(OH) 2 D 3 , 3α-25(OH)D 3 , 3β-25(OH)D 3 , and vitamin D 3 using a C-18 column with methanol/water gradient elution. The described duplex derivatization was tested on 40 serum samples of patients with chronic liver diseases (CLD). Additionally, the method was evaluated in terms of linearity, accuracy, precision, and interferences between heavy and light tag samples using both commercial quality control samples and in-house quality control and calibration samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.