1998
DOI: 10.1088/0031-8949/57/4/004
|View full text |Cite
|
Sign up to set email alerts
|

Stark Widths and Oscillator Strengths of Xe III Lines (Part II)

Abstract: Stark widths and relative oscillator strengths were measured for more than 130 Xe III spectral lines emitted in a pulsed capillary discharge. As usual, these parameters become attainable once the deconvolution of line profiles is performed. In particular, 4f–6d, 5d–4f, 5d–6p, 6p–6d, 6p–7s and 6s–4f Xe III transitions have been considered. Extensive configuration interaction (CI) along with least-squares fitted atomic parameters were combined in Cowan code calculations, in order to check the quality of agreemen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0

Year Published

2000
2000
2009
2009

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 8 publications
1
12
0
Order By: Relevance
“…The measured data are classified depending on the experimental error estimation as A (6-10%), B (10-15%) and C (15-20%). The last three columns contain the data of halfwidth measurements from other authors [8][9][10][11]. Different authors performed their measurements at different temperatures, while our measurements are given for the temperature of 22 000 K. All data are normalized to an electron density of 10 23 m −3 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The measured data are classified depending on the experimental error estimation as A (6-10%), B (10-15%) and C (15-20%). The last three columns contain the data of halfwidth measurements from other authors [8][9][10][11]. Different authors performed their measurements at different temperatures, while our measurements are given for the temperature of 22 000 K. All data are normalized to an electron density of 10 23 m −3 .…”
Section: Resultsmentioning
confidence: 99%
“…Measurements were performed using a pulsed plasma source. Plasma diagnostics data are as follows: electron densities, determined by the two wavelengths interferometric method, were in the range of (0.2-1.6) × 10 23 m −3 , while electron temperatures, determined by the Boltzmann plot technique, were between 18 300 K and 25 500 K. Obtained experimental results are compared with available experimental data of other authors [8][9][10][11] and theoretical calculations based on [12].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Stark broadening and shift of ionized Xe spectral lines have been the subject of many experimental [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20] and theoretical [20,21] studies, as was previously mentioned in [22,23]. Examination of an ionized xenon spectrum is of great interest for laser techniques [24,25], development of light sources and lamps [26][27][28] or astrophysics [29][30][31][32][33][34][35][36].…”
Section: Introductionmentioning
confidence: 99%
“…Most of the papers dealing with the Stark broadening of Xe II lines [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][21][22][23] and Xe III lines [17][18][19][20] are devoted to width measurements. Only three papers [6,15,16] give the results of Xe II shift measurements and only one paper [10] gives the results of Xe III shift measurements.…”
Section: Introductionmentioning
confidence: 99%