2017
DOI: 10.1063/1.4984542
|View full text |Cite
|
Sign up to set email alerts
|

Start-up performance of parabolic trough concentrating solar power plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…Figure 8 illustrates an analysis similar to the one described in section 3.1 but for a solar-driven operational strategy. The reference case adopted was for a SM equal to 2, being a representative value for existing power plant configurations like Andasol (Ferruzza et al, 2017). Following a similar consideration as before, if only hot evaporator start-ups are considered, the results indicate that the potential for improvement of the net electricity production is as low as 0.27 % (0.56GWhe), while for cold start-ups, this impact increases to a maximum of 2.3 %.…”
mentioning
confidence: 86%
See 2 more Smart Citations
“…Figure 8 illustrates an analysis similar to the one described in section 3.1 but for a solar-driven operational strategy. The reference case adopted was for a SM equal to 2, being a representative value for existing power plant configurations like Andasol (Ferruzza et al, 2017). Following a similar consideration as before, if only hot evaporator start-ups are considered, the results indicate that the potential for improvement of the net electricity production is as low as 0.27 % (0.56GWhe), while for cold start-ups, this impact increases to a maximum of 2.3 %.…”
mentioning
confidence: 86%
“…The author implemented the parabolic trough sizing methodology and the TRNSYS model in DYESOPT and validated against data available in literature with a maximum error of -8.9 % (Ferruzza et al, 2017).…”
Section: Plant Design Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…In that work, all the components of the power block are modeled. In [42], a complex and detailed model developed in TRNSYS of the steam generator is presented to study the start-up stage. In [40], a complex model of a steam turbine is developed.…”
Section: Modeling Of the Steam Generator Variablesmentioning
confidence: 99%
“…The model presented and validated in Ref. [8] was modified to account for a new direct storage configuration as well as an adapted freeze protection system (electric heat tracing). The layouts of the analyzed power plants are shown in FIGURE 1.…”
Section: Modelling and Design Of The Parabolic Trough Power Plantsmentioning
confidence: 99%