2000
DOI: 10.1109/61.891520
|View full text |Cite
|
Sign up to set email alerts
|

STATCOM control for power system voltage control applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
151
0
3

Year Published

2008
2008
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 403 publications
(165 citation statements)
references
References 6 publications
0
151
0
3
Order By: Relevance
“…Thus, the reliability and security cannot be guaranteed when the network voltage exceeds the rated voltage of each cluster. As a result, the PCU between different voltage levels is incompatible in most present SVG projects [12][13][14][15][16].…”
Section: Mathematical Problems In Engineeringmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, the reliability and security cannot be guaranteed when the network voltage exceeds the rated voltage of each cluster. As a result, the PCU between different voltage levels is incompatible in most present SVG projects [12][13][14][15][16].…”
Section: Mathematical Problems In Engineeringmentioning
confidence: 99%
“…Thus, a lot of advanced methods combined with PI controller are trying to overcome these problems, such as particle swarm optimization [9], neural networks [10], and artificial immunity [11]. In literature [12], adaptive control and linear robust control have been reported for their antiexternal disturbance ability. In literature [13], a popular dead-beat current controller is used.…”
Section: Introductionmentioning
confidence: 99%
“…Rewrite the cost function in format of (10), it shows that the new LQR regulator is aimed in minimize the errors.…”
Section: A Hybrid Fuzzy/lqr Realizationmentioning
confidence: 99%
“…As a promising technology, the control of STATCOM has been discussed in many literatures [7][8][9][10]. In this paper, the damping of torsional oscillations using STATCOM, connected at the middle bus is studied.…”
Section: Introductionmentioning
confidence: 99%
“…PID controller has been selected because of few reasons: (i) the settling time is faster than PI and PD controllers, (ii) less percent overshoot, (iii) faster time to steady state [6], and (iv) the response time is less than PI controller which is about 0.1sec [7] and this is an important parameter to voltage sag/fault. The function of poles and zeros arrangement is used to shift the initial poles from the right to the left of the complex diagram, in order to increase the stability of the system.…”
mentioning
confidence: 99%