2012
DOI: 10.1021/ac203451g
|View full text |Cite
|
Sign up to set email alerts
|

State-of-the Art Comparability of Corrected Emission Spectra. 2. Field Laboratory Assessment of Calibration Performance Using Spectral Fluorescence Standards

Abstract: /npsi/ctrl?action=rtdoc&an=21268134&lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=21268134&lang=fr READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE.http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en Vous avez des questions? Nous pouvons vous aider. Pour communiquer directement avec un auteur, consultez la première page de la revue dans laquelle son article a été publié afin de trouver ses coordonnées. Si vous n'arrivez pas à les repérer, communi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 17 publications
(22 citation statements)
references
References 33 publications
0
22
0
Order By: Relevance
“…The excitation and the emission sides of the instrument must be spectrally calibrated according to standard methods [12,[16][17][18][20][21][22][23]. .…”
Section: The Raman Integral Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The excitation and the emission sides of the instrument must be spectrally calibrated according to standard methods [12,[16][17][18][20][21][22][23]. .…”
Section: The Raman Integral Methodsmentioning
confidence: 99%
“…To date, no such multi-fluorophore standards exist, and consequently both excitation and emission should be calibrated independently using conventional procedures. The reader is directed elsewhere for more detailed discussion of the aspects of standard spectral correction [12,[16][17][18][19][20][21][22][23].…”
Section: Instrumental Calibrationmentioning
confidence: 99%
“…Simple procedures for the determination of the (relative) spectral responsivity were only recently assessed in two international comparisons, one comparison involving four National Metrology Institutes and in another comparison involving several field laboratories randomly chosen from academia and industry [59,60]. The used and evaluated fluorescence standards, the BAM Kit Spectral Fluorescence Standards covering the spectral region from 300 to 770 nm, are commercially available.…”
Section: Iii21 Spectrofluorometermentioning
confidence: 99%
“…The spectral responsivity of the emission channel always depends on both wavelength and polarization. Both dependences can be accounted for by excitation and emission correction curves [36,48,55,56,[58][59][60]. Sample-related polarization effects reflect the size of the fluorescence anisotropy or (de)polarization of the sample [1].…”
Section: Iii43 Use Of Polarizers and Instrument-and Sample-related mentioning
confidence: 99%
See 1 more Smart Citation