2021
DOI: 10.1093/ehjci/jeab040
|View full text |Cite
|
Sign up to set email alerts
|

State-of-the-art intra-procedural imaging for the mitral and tricuspid PASCAL Repair System

Abstract: Advanced intra-procedural imaging techniques have been integral to technical and procedural success transcatheter devices. A novel leaflet approximation therapy, the PASCAL Transcatheter Valve Repair System (Edwards Lifesciences, Irvine, CA, USA) has demonstrated high procedural success, acceptable safety, and significant clinical improvement in patients with severe mitral and tricuspid regurgitation and has CE mark approval in Europe with pivotal trials underway in the USA. This review outlines the pre-proced… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
16
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 35 publications
0
16
0
Order By: Relevance
“… 12 Advanced transesophageal echocardiography (TEE) with 2D and 3D multiplanar reconstruction (MPR) is a key component for transcatheter tricuspid procedures and may be most critical in TEER, as appropriate device alignment and leaflet capture are essential. 13 There are many factors in procedural imaging that may impact appropriate TEE visibility of leaflets when performing a tricuspid TEER procedure. These include shadowing from left-sided surgical aortic and mitral prostheses, tricuspid annular bands/rings, atrial septal hypertrophy, as well as anatomic thoracic features such as a horizontal heart axis, hiatal hernias, or additional thoracic/esophageal pathology.…”
mentioning
confidence: 99%
“… 12 Advanced transesophageal echocardiography (TEE) with 2D and 3D multiplanar reconstruction (MPR) is a key component for transcatheter tricuspid procedures and may be most critical in TEER, as appropriate device alignment and leaflet capture are essential. 13 There are many factors in procedural imaging that may impact appropriate TEE visibility of leaflets when performing a tricuspid TEER procedure. These include shadowing from left-sided surgical aortic and mitral prostheses, tricuspid annular bands/rings, atrial septal hypertrophy, as well as anatomic thoracic features such as a horizontal heart axis, hiatal hernias, or additional thoracic/esophageal pathology.…”
mentioning
confidence: 99%
“…Numerous research has looked into the impact of utilizing various VC width and EROA cutoffs in this setting. They consistently demonstrated a poorer prognosis for patients with either massive or torrential TR 15–18 …”
Section: Discussionmentioning
confidence: 98%
“…They consistently demonstrated a poorer prognosis for patients with either massive or torrential TR. [15][16][17][18] Over the past 20-25 years, cardiovascular magnetic resonance (CMR) has established itself as the gold standard for assessing left and right ventricular mass, volume, and function. Additionally, it has developed into a trustworthy and precise tool for calculating the volumetric quantification of the heart valves utilizing a number of methods that are independent of jet morphology.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations