1994
DOI: 10.1051/jp2:1994218
|View full text |Cite
|
Sign up to set email alerts
|

Static light scattering and electric birefringence experiments on saltfree solutions of poly(styrenesulfonate)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
30
1

Year Published

1997
1997
2017
2017

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 18 publications
(36 citation statements)
references
References 0 publications
5
30
1
Order By: Relevance
“…With increasing concentration the relaxation time increases, even though the sign of the birefringence changes. This is clearly different from the behaviour of PSS found by Kramer and Hoffmann [52] and Johner et al, [53] where similar anomalous behaviour is coupled with a decrease in relaxation times. By contrast, within experimental limit, s 1 is independent of field strength, concentration and also molecular weight, and is therefore unaffected by the aggregation to gelation phenomena suggested by the change in sign of the birefringence.…”
Section: Decay Kineticscontrasting
confidence: 98%
See 4 more Smart Citations
“…With increasing concentration the relaxation time increases, even though the sign of the birefringence changes. This is clearly different from the behaviour of PSS found by Kramer and Hoffmann [52] and Johner et al, [53] where similar anomalous behaviour is coupled with a decrease in relaxation times. By contrast, within experimental limit, s 1 is independent of field strength, concentration and also molecular weight, and is therefore unaffected by the aggregation to gelation phenomena suggested by the change in sign of the birefringence.…”
Section: Decay Kineticscontrasting
confidence: 98%
“…The measured s 2 values for 34.7 6 10 3 ZT-PS are comparable to those obtained for PSS by Kramer and Hoffmann [52] and also high-molecular-weight normal PS, [85] but less than those obtained for PSS by Johner et al [53] The differences between the PSS systems can be explained by the differences in ionic strength between the two polymers used which affects the particle-particle interaction, and therefore the relaxation rates. [53] Assuming a non-free draining bead-spring model values of s = 122-642 ls have been calculated for normal (unfunctionalised) polystyrene in a good solvent for molecular weights of 5.4-15.3) 6 10 6 g N mol -1 , respectively.…”
Section: Decay Kineticssupporting
confidence: 79%
See 3 more Smart Citations