2016
DOI: 10.21037/tlcr.2016.09.04
|View full text |Cite
|
Sign up to set email alerts
|

Statistical control process to compare and rank treatment plans in radiation oncology: impact of heterogeneity correction on treatment planning in lung cancer

Abstract: The statistical analysis using Cp and Cpk, show the significance of dose differences resulting from two plans in radiotherapy. These indices can be used for adaptive radiotherapy to measure the difference between initial plan and daily delivered plan. The significant changes of dose distribution could raise the question about the continuity to treat the patient with the initial plan or the need for adjustments.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…For IMRT QA using the Gafchromic EBT3 film dosimetry, it requires an efficient data analysis tool. 41,42 GAH is an efficient tool to calculate DD for IMRT QA because it can indicate the region where calculated dose differs from the measurement. The DDs calculated by GAHs have to ensure that the dimensions are properly registered with planned dose within the analysing software so that we can approximate the limits of dose beam modelling and calculation algorithms.…”
Section: Resultsmentioning
confidence: 99%
“…For IMRT QA using the Gafchromic EBT3 film dosimetry, it requires an efficient data analysis tool. 41,42 GAH is an efficient tool to calculate DD for IMRT QA because it can indicate the region where calculated dose differs from the measurement. The DDs calculated by GAHs have to ensure that the dimensions are properly registered with planned dose within the analysing software so that we can approximate the limits of dose beam modelling and calculation algorithms.…”
Section: Resultsmentioning
confidence: 99%
“…The process capability index (Cpk) that represented the process behavior was utilized to assess the state of QC process. The Cpk demonstrated how data set closed to CL when considering its mean (15,28) . If the Cpk was more than 1, the process variation was within the specification limits.…”
Section: Data Collection and Analysismentioning
confidence: 99%
“…Compared to the number of articles and conference abstracts for radiation therapy using SPC, the proportion of setup uncertainty in radiation therapy is 14.71% as shown in figure 1. A plethora of papers reports the SPC is applied comprehensively to QC and QA for beam output and symmetry, dose, treatment plan and proton beam range design in radiotherapy, but less for NPC patient setup uncertainty (13)(14)(15)(16) . This is beyond our expectation, so it necessitates us paying more attention to NPC patient positioning reproducibility using SPC tools.…”
Section: Introductionmentioning
confidence: 99%