2001
DOI: 10.1093/aje/154.2.174
|View full text |Cite
|
Sign up to set email alerts
|

Statistical Inference for the Area under the Receiver Operating Characteristic Curve in the Presence of Random Measurement Error

Abstract: The area under the receiver operating characteristic curve is the most commonly used measure of the ability of a biomarker to distinguish between two populations. Some markers are subject to substantial measurement error. Under normality assumptions, the authors develop a confidence interval procedure for the area under the receiver operating characteristic curve that adjusts for measurement error. This procedure assumes the availability of data from a reliability study of the biomarker. A simulation study was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
100
0
12

Year Published

2003
2003
2017
2017

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 98 publications
(113 citation statements)
references
References 15 publications
1
100
0
12
Order By: Relevance
“…Portanto, neste estudo, o Índice C foi considerado bom preditor quando seu intervalo de confiança (IC) for superior a 0,50 e a área sob a curva ROC for superior a 0,60. O IC determina se a capacidade preditiva do indicador antropométrico não é devido ao acaso e o seu limite inferior não deve ser menor que 0,50 23 . Neste estudo, utilizou-se um intervalo com 95% de confiança (IC95%).…”
Section: Cad Saúde Pública 2017; 33(3):e00029316unclassified
“…Portanto, neste estudo, o Índice C foi considerado bom preditor quando seu intervalo de confiança (IC) for superior a 0,50 e a área sob a curva ROC for superior a 0,60. O IC determina se a capacidade preditiva do indicador antropométrico não é devido ao acaso e o seu limite inferior não deve ser menor que 0,50 23 . Neste estudo, utilizou-se um intervalo com 95% de confiança (IC95%).…”
Section: Cad Saúde Pública 2017; 33(3):e00029316unclassified
“…It is worth mentioning that instead of using all non-gaze saliency values, these are usually sampled [17], [75]. The idea behind this approach is that an effective saliency model would have higher values at fixation points than at randomly sampled points.…”
Section: ) Area Under Curve (Auc)mentioning
confidence: 99%
“…Quanto maior a área sob a curva ROC, maior o poder discriminatório dos escores da qualidade de vida para a maior distância no TC6' dos pacientes com IC. O intervalo de confiança de 95% (IC 95%) determina a capacidade preditiva do indicador dos escores da QV, sendo que seu limite inferior não deve ser menor do que 0,50 (29). Para identificar a diferença das áreas sob as curvas ROC utilizou-se o teste do qui-quadrado.…”
Section: Análise Estatísticaunclassified