The objective of this paper is to apply Principal Component Analysis to evaluate the aging state of the insulation system of the generators of Salto Grande identifying the mostly aged units. This hydropower plant has 14 generators of 135 MW each, with an average age of 32 years. From the analysis it was concluded that there is no evidence of critical units, which require rapid intervention. But there is an aging process, which is not equal on all generators, as there are generators showing a more advanced aging stage. This is key information to define a work plan for maintenance, or to recommend detailed inspections by specialists, or define an upgrade plan.
Resumen-El objetivo de este trabajo es aplicar Análisis deComponentes Principales para evaluar el estado de envejecimiento del sistema aislante de los generadores de Salto Grande e identificar las unidades mayormente envejecidas. Dicha central hidroeléctrica posee 14 generadores de 135 MW cada uno y con una edad promedio de 32 años. Del análisis realizado se concluyó que no hay indicios de unidades críticas, las cuales necesiten una rápida intervención. Pero existe un proceso de envejecimiento, el cual no es parejo en todos los generadores, evidenciando generadores con un estado de envejecimiento más avanzado. Esta es una información clave para definir un plan de trabajo en mantenimiento, para recomendar inspecciones detalladas por especialistas o definir un plan de renovación de las unidades.