Status of SPIDER beam source after the first 3.5 years of operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 20 publications
1
3
0
Order By: Relevance
“…Due to air and water leaks, thick solid composites were found inside the oven reservoir and the estimation of the caesium consumption (by measuring the weight of the reservoid) to confirm the flow measured by the surface ionization detector was not possible. The caesium density measured by the laser absorption spectroscopy between plasma pulses, and the ceasium amount measured at the stains found at the extraction grid surfaces [17], were found to be in good agreement with the results of simulations (figure 2(a)) of caesium evaporation in vacuum [19].…”
Section: Control Of Caesium Evaporation and Improvement Of The Emissi...supporting
confidence: 71%
See 1 more Smart Citation
“…Due to air and water leaks, thick solid composites were found inside the oven reservoir and the estimation of the caesium consumption (by measuring the weight of the reservoid) to confirm the flow measured by the surface ionization detector was not possible. The caesium density measured by the laser absorption spectroscopy between plasma pulses, and the ceasium amount measured at the stains found at the extraction grid surfaces [17], were found to be in good agreement with the results of simulations (figure 2(a)) of caesium evaporation in vacuum [19].…”
Section: Control Of Caesium Evaporation and Improvement Of The Emissi...supporting
confidence: 71%
“…While operating SPIDER in short pulses, it was found that the characteristics of the caesium flux from the caesium delivery system between plasma discharges was of great importance and could affect the beam uniformity and the capability of the plasma to redistribute the caesium [4]. Caesium distribution was studied density during operation [15,16], as well as after the end of the operations with visual inspections and analyses of the ion source walls [17,18]. It was found that the oven nozzle evaporated the largest caesium amount onto the surfaces in the proximity of the nozzle, creating stains that were clearly visible once the source was opened.…”
Section: Control Of Caesium Evaporation and Improvement Of The Emissi...mentioning
confidence: 99%
“…It highlights that the metallic components in correspondence to the fourth segments are shiny, i.e. Cs coverage is poor, compared to the other segments, where the presence of Cs is recognizable from the matted effect of the PG and bias plate surfaces [19]. The reason behind the strong removal of Cs and/or poor deposition on the bottom segment is not known.…”
Section: Jinst 18 C09006mentioning
confidence: 97%
“…Here we present the ratio between Cs and Mo concentration, even though similar results are obtained considering the sole Cs concentrations. The whole process is described in detail in [20]. Due to the closeness of the permanent magnets, it was possible to collect only one sample at the position of each magnet and one sample between each magnet.…”
Section: Cs On the Source Case Lateral Wall (Sclw)mentioning
confidence: 99%