2000
DOI: 10.1016/s0168-583x(00)00208-1
|View full text |Cite
|
Sign up to set email alerts
|

Status of the 36Cl AMS system at the University of Tsukuba

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 5 publications
1
9
0
Order By: Relevance
“…In addition, significant amounts of 36 Cl were produced by neutron activation of 35 Cl in 10 seawater during thermonuclear testing on small islands or on barges (primarily between 1954 11 and 1958), and this bomb-36 Cl was injected into the atmosphere [10]. Fallout of this bomb- 36 Cl 12 has been preserved in ice cores, e.g., the Dye-3 cores from Greenland [11,12], show a 36 Cl peak 13 in the late 1950s (several years prior to the 3 H peak). The bomb-pulse 36 Cl is thought to have a 14 latitudinal distribution with greatest deposition at mid-latitudes [10].…”
Section: Introduction 17mentioning
confidence: 99%
“…In addition, significant amounts of 36 Cl were produced by neutron activation of 35 Cl in 10 seawater during thermonuclear testing on small islands or on barges (primarily between 1954 11 and 1958), and this bomb-36 Cl was injected into the atmosphere [10]. Fallout of this bomb- 36 Cl 12 has been preserved in ice cores, e.g., the Dye-3 cores from Greenland [11,12], show a 36 Cl peak 13 in the late 1950s (several years prior to the 3 H peak). The bomb-pulse 36 Cl is thought to have a 14 latitudinal distribution with greatest deposition at mid-latitudes [10].…”
Section: Introduction 17mentioning
confidence: 99%
“…The 36 Cl/Cl ratios were measured by the Tsukuba AMS system at the Tandem Accelerator Complex, University of Tsukuba (Nagashima et al, 2000;Sasa et al, 2007). The 36 S interference was corrected by using a blank sample prepared from NaCl reagent; typical correction rate was 10% for samples with a 36 Cl/Cl ratio of 1 × 10 12 .…”
Section: Analyses Of Samplesmentioning
confidence: 99%
“…The obtained 36 Cl/Cl ratio of the sample includes statistical error derived from uncertainties (1 ) of the sample, the standard and the blank. Details of the measurement and the 36 Cl/Cl calculations have been given in Nagashima et al (2000Nagashima et al ( , 2004. The overall precision of the system is better than 5%, and the background level of 36 Cl/Cl measurement is below 2 × 10 14 .…”
Section: Analyses Of Samplesmentioning
confidence: 99%
“…The method was described previously [10]. A 'tri-molecular pilot beam' method is used to stabilize the terminal voltage.…”
Section: Measurement Of 36 CLmentioning
confidence: 99%