Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up

Abstract: ObjectiveTo determine, by means of long-term follow-up evaluation, the outcome and accuracy of stereotactic core-needle biopsy (SCNB) of non-mass calcifications observed at mammography, and to analyze the factors contributing to false-negative findings.Materials and MethodsUsing a 14-gauge needle, SCNB was performed in cases involving 271 non-mass calcified lesions observed at mammography in 267 patients aged 23-72 (mean, 47) years. We compared the SCNB results with those of long-term follow-up which included … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
1
2

Year Published

2005
2005
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 22 publications
1
9
1
2
Order By: Relevance
“…Any benign lesion from stereotactic biopsy was not confirmed by surgery. Therefore, for confident conclusions, continuous follow-ups are required (6, 18, 19). …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Any benign lesion from stereotactic biopsy was not confirmed by surgery. Therefore, for confident conclusions, continuous follow-ups are required (6, 18, 19). …”
Section: Discussionmentioning
confidence: 99%
“…In addition, the prone position allows an approach from all directions, including vertical and lateral approaches. Studies analyzing the utility of stereotactic breast biopsies in Asian women are scarce, and in the few published studies, only cases using the add-on stereotactic method (5) rather than the prone position have been examined, even in procedures involving core needle biopsies (6). We know of no prior articles in which the utility of prone stereotactic vacuum-assisted breast biopsies using a lateral approach has been evaluated.…”
Section: Introductionmentioning
confidence: 99%
“…The sampling methods include the widely practiced stereotactic needle core biopsy and mammotome, with the latter usually giving larger core size samples. In general, the retrieval of calcifications at stereotactic needle core biopsy is satisfactory, ranging from about 77% to almost 100%, with a mean value of about 86% [46][47][48][49].…”
Section: Calcification and Biopsymentioning
confidence: 99%
“…It is not surprising to see this discrepancy as previous studies analyzed methanol extracts while the current study was focused on water extract. Several studies have demonstrated that gallic acid [44,45] and paeoniflorin [46] prevent weight gain, inhibit adipocyte proliferation, induce adipolysis, and lower blood lipids. To our knowledge, saccharides do not have weight-and lipid-lowering properties.…”
Section: Discussionmentioning