Steroid-eluting contact lenses for corneal and intraocular inflammation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
25
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(28 citation statements)
references
References 74 publications
3
25
0
Order By: Relevance
“…Consistent with other research results, compared with eye drop, SCLs significantly prolonged retention time of PFD in vitro and in vivo (Maulvi et al, 2018;Gote et al, 2019;Bengani et al, 2020;Zhang et al, 2020). Thicker SCLs slowed down drug release in vitro, because molecules of drug within Cell viability of HCE-T cells were above 90% and had no significant change at all measured time points compared with control group; (B) the measured thickness of corneas of rabbits before and after safety test, the data was shown as mean ± SDs (n ¼ 6, ÃÃÃ P < .001); (C) picture of measured thickness of corneas of rabbits before the test (祄¼lm); (D) picture of measured thickness of corneas of rabbits after the test (祄¼lm); (E) histological picture of corneas of rabbits after wearing SCLs for consecutive seven days; (F) picture of histology of irises of rabbits after wearing SCLs for consecutive seven days.…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…Consistent with other research results, compared with eye drop, SCLs significantly prolonged retention time of PFD in vitro and in vivo (Maulvi et al, 2018;Gote et al, 2019;Bengani et al, 2020;Zhang et al, 2020). Thicker SCLs slowed down drug release in vitro, because molecules of drug within Cell viability of HCE-T cells were above 90% and had no significant change at all measured time points compared with control group; (B) the measured thickness of corneas of rabbits before and after safety test, the data was shown as mean ± SDs (n ¼ 6, ÃÃÃ P < .001); (C) picture of measured thickness of corneas of rabbits before the test (祄¼lm); (D) picture of measured thickness of corneas of rabbits after the test (祄¼lm); (E) histological picture of corneas of rabbits after wearing SCLs for consecutive seven days; (F) picture of histology of irises of rabbits after wearing SCLs for consecutive seven days.…”
Section: Discussionsupporting
confidence: 90%
“…Also, there are various innovated SCLs for ocular drug delivery in recent years to improve bioavailability. Researchers have made important progress in prolonging functional time of drugs in vitro an in vivo (Maulvi et al, 2018;Gote et al, 2019;Bengani et al, 2020;Zhang et al, 2020). In this study, we increased drug loading capacity in PVA film embedded SCLs, and evaluated drug release in vitro and in vivo.…”
Section: Discussionmentioning
confidence: 99%
“…The scores involve weighting and summing six components of directly observable changes of the eye's anterior segment, including the density and area of corneal opacification, severity of iritis, conjunctival redness, edema, and discharge. [31][32][33][34][35][36]…”
Section: Ocular Toxicology: the Draize Eye Testmentioning
confidence: 99%
“…However, the results have shown that the amount of active substances that are resorbed and released are too small to have any clinical significance and to create a controlled drug release, the contact lenses need to be modified for the purpose (Bengani et al. 2020; Zhang et al. 2020).…”
Section: Introductionmentioning
confidence: 99%
“…To increase the bioavailability of ocular drugs, many attempts have been made to load existing contact lens types by soaking them in ophthalmic solutions. However, the results have shown that the amount of active substances that are resorbed and released are too small to have any clinical significance and to create a controlled drug release, the contact lenses need to be modified for the purpose (Bengani et al 2020;Zhang et al 2020). Most studies on the effects of ophthalmic solutions on contact lenses are performed in vitro.…”
Section: Introductionmentioning
confidence: 99%