2010
DOI: 10.1002/jmri.22182
|View full text |Cite
|
Sign up to set email alerts
|

Stimulated echo induced misestimates on diffusion tensor indices and its remedy

Abstract: Purpose: To report possible erroneous estimates of diffusion parameters in the twice-refocused spin-echo (TRSE) technique, proposed to eliminate eddy-current-induced geometric distortions in diffusion-weighted echo-planar imaging, when stimulated echo signals are inappropriately included.Materials and Methods: Eleven subjects were included for imaging experiments on two 1.5 Tesla systems using the TRSE sequence. Three versions, two with unbalanced crusher gradients inserted to dephase the stimulated echo from … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…Smart reordering of the phase encoding steps allows a separation of phase error and T2 modulation in the k-space (10), hence permitting appropriate manipulation and filtering of the k-space data differently along the two phase-encoding directions to minimize artifacts (30). T2related blurring can be further reduced using variable flip angle for the refocusing pulses (31) in a way to incorporate stimulated echo signals into the echo train (32). Along with the multiple gradient-echoes that effectively increase acquisition efficiency, 3D imaging at reduced scan time with stability approaching that of FSE becomes a possibility at high field strengths.…”
Section: Unique Advantages Of Grasementioning
confidence: 99%
“…Smart reordering of the phase encoding steps allows a separation of phase error and T2 modulation in the k-space (10), hence permitting appropriate manipulation and filtering of the k-space data differently along the two phase-encoding directions to minimize artifacts (30). T2related blurring can be further reduced using variable flip angle for the refocusing pulses (31) in a way to incorporate stimulated echo signals into the echo train (32). Along with the multiple gradient-echoes that effectively increase acquisition efficiency, 3D imaging at reduced scan time with stability approaching that of FSE becomes a possibility at high field strengths.…”
Section: Unique Advantages Of Grasementioning
confidence: 99%
“…Therefore, evaluating the DWI characteristics of gliomas in a larger patient cohort is a clinically demanding task. Considering possible variations of the technical factors, such as the b value for diffusion weighting 11 or eddy-current-related geometric distortions/corrections that might affect the quantification of ADC, 12,13 DWI which is less sensitive to scan settings would be preferential over ADC. In a recent study by El Kady et al, ADC values measured on a routine picture archiving and communicating system (PACS) workstation proved to be as accurate as the values obtained using a dedicated specialized workstation.…”
Section: Introductionmentioning
confidence: 99%