1978
DOI: 10.1002/jbm.820120612
|View full text |Cite
|
Sign up to set email alerts
|

Stimulation of bone formation by a swelling endosseous implant

Abstract: As previously reported,'q2 a polymer-ceramic composite designed for endosseous implant applications has been developed. The composites were prepared by the free-radical polymerization of an acrylic acid solution and a difunctional acrylate in the presence of 0.3 pm akunina powder. Mechanical testing indicated that the material had a compressive yield strength of 89-102 MPa (13-15 ksi) and an elastic modulus of 2055-2740 MPa (300-400 ksi). The average porosity of the composite was determined to be in the range … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
24
0

Year Published

1997
1997
2002
2002

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 18 publications
(25 citation statements)
references
References 6 publications
1
24
0
Order By: Relevance
“…It has been reported that AMA is a fairly good cross-linker for PAA [1][2][3] and a relatively weak The fact that these clusters were unreacted monomers (not initiator) was ascertained from the cross-linker for PMMA. 10 It has also been reported 10 that DEGDMA is a better cross-linker smell of the liquid in these clusters and noting that the initiator used here is solid.…”
Section: Polymer Characterizationmentioning
confidence: 99%
See 4 more Smart Citations
“…It has been reported that AMA is a fairly good cross-linker for PAA [1][2][3] and a relatively weak The fact that these clusters were unreacted monomers (not initiator) was ascertained from the cross-linker for PMMA. 10 It has also been reported 10 that DEGDMA is a better cross-linker smell of the liquid in these clusters and noting that the initiator used here is solid.…”
Section: Polymer Characterizationmentioning
confidence: 99%
“…1 These swelling-type im-(this determines how long the patient has to be plants were proposed as means of enhancing the bedridden); low loss of mechanical properties fixation characteristics of implants in bone. The with swelling; elastic stiffness close to that of bone concept involved swelling of the implant by ab-(high stiffness of current metallic implants is sorption of body fluids and achieving fixation at known to cause bone resorption due to stress the implant-bone interface by an expansion-fit shielding); and excellent failure resistant propermechanism.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations