Stimulation Waveform Selection to Suppress Functional Electrical Stimulation Artifact from Surface EMG Signals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…with a webcam) and to analyse the video with automatic facial action coding, for which several software packages exist (Cheong et al, 2021;Dupré et al, 2020). Finally, additional electrodes might be placed near the fNMES electrodes to record electromyographyhowever, this can be a challenge given the small facial area, and will require cleaning the signal from the important NMES-induced artefacts (Rantanen et al, 2018).…”
Section: Motor Point Identificationmentioning
confidence: 99%
See 3 more Smart Citations
“…with a webcam) and to analyse the video with automatic facial action coding, for which several software packages exist (Cheong et al, 2021;Dupré et al, 2020). Finally, additional electrodes might be placed near the fNMES electrodes to record electromyographyhowever, this can be a challenge given the small facial area, and will require cleaning the signal from the important NMES-induced artefacts (Rantanen et al, 2018).…”
Section: Motor Point Identificationmentioning
confidence: 99%
“…it was only described as "symmetrical" (e.g. Sapphire, which according to its user manual uses a square wave); 6) in case of polyphasic waveforms (Rantanen et al 2018;Ilves et al, 2020), we provided the frequency of the pulse train, and not of the pulses inside of polyphasic "packages"; 7) if several amplitudes were used, we noted the largest one; 8) separate entries were created if a study included several experiments with different parameters. Once completed, Table 1 was loaded into R, where we computed duty cycle, Irms/cm 2 based on the formulas provided below (section Formulas), unless relevant parameters were missing, which unfortunately was the case for the large majorities (27 of the 34) of studies.…”
Section: Systematic Reviewmentioning
confidence: 99%
See 2 more Smart Citations
“…Simple low-order filters are also an option if the stimulation waveform is properly chosen. For example, wavelets that have highfrequency components can be used [26]. However, the waveform should not have a negative impact on the intensity of the evoked muscle movement compared to more conventional FES waveforms that are simple biphasic square wave pulses with more power at low frequencies.…”
Section: Introductionmentioning
confidence: 99%