2002
DOI: 10.1016/s0039-9140(02)00441-1
|View full text |Cite
|
Sign up to set email alerts
|

Stopped-flow injection simultaneous determination of phosphate and silicate using molybdenum blue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0
1

Year Published

2004
2004
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 49 publications
(16 citation statements)
references
References 18 publications
0
15
0
1
Order By: Relevance
“…The stopped flow injection method can increase sensitivity of the measurement by increasing the residence time [16,17]. Travelling time is the time from injection to the stopping time depend on the physical parameters in which increase with increase reaction coil and sample manifolds parameters, the travelling time after each injection was studied and established that sample zone achieved the flow cell 30 and 25 s of the two methods after each injection and the time intervals between stopping and resuming the pump flow, in the range (10-260 s) were also studied, it was injected 30 µg mL -1 for method A, 35 µg mL -1 for method B.…”
Section: Supplements Diatery Preparationmentioning
confidence: 99%
“…The stopped flow injection method can increase sensitivity of the measurement by increasing the residence time [16,17]. Travelling time is the time from injection to the stopping time depend on the physical parameters in which increase with increase reaction coil and sample manifolds parameters, the travelling time after each injection was studied and established that sample zone achieved the flow cell 30 and 25 s of the two methods after each injection and the time intervals between stopping and resuming the pump flow, in the range (10-260 s) were also studied, it was injected 30 µg mL -1 for method A, 35 µg mL -1 for method B.…”
Section: Supplements Diatery Preparationmentioning
confidence: 99%
“…By stopping the flow the residence time can be prolonged without increasing the length of the reaction coil, thus avoiding an increase of dispersion [21,22] Travelling time " period from the injection to the stopping time" depend on the physical parameters in which increase with increase reaction coil and sample manifolds parameters, the travelling time after each injection was studies and it was found that the sample zone reached the flow cell 30 sec after each injection, and the time intervals between stopping and restarting the pump flow, in the range(10-100sec) was also studies, it found after 50 sec ( Figure 3) the stopping time this time was selected as the optimum interval time. …”
Section: Figurementioning
confidence: 99%
“…The main interferences in the phosphorus determination by the molybdenum blue method in soil extracts are orthosilicate ions via the formation of silicic molybdic acid, 25 dissolved organic matter 26 and metallic ions that can precipitate as phosphates.…”
Section: Interference Studiesmentioning
confidence: 99%