2022
DOI: 10.1080/09273972.2022.2157023
|View full text |Cite
|
Sign up to set email alerts
|

Strabismus and amblyopia in Africa – a systematic review and meta-analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 69 publications
0
4
0
Order By: Relevance
“…A highly detailed image of the pupil is obtained, which enables an algorithm to detect adjusting movements of less than 0.2 mm, difficult to observe during a traditional PCT examination (Figure 3). 5) adapter for trial lenses, (6) LCD shutters, (7) hot mirror, (8) drive system allowing the optics to be adjusted to the user's pupillary distance, (9) NIR LED illuminator, (10) movable fixing element for optical components, (11) fixation point for the non-fixing eye, (12) fixation point for the fixing eye. The pupil distance can be set from 53 to 82 mm and is taken into account when setting the following fixation point positions on the test screen, increasing the reliability of the results in both children and adults.…”
Section: Construction Of the Devicementioning
confidence: 99%
See 3 more Smart Citations
“…A highly detailed image of the pupil is obtained, which enables an algorithm to detect adjusting movements of less than 0.2 mm, difficult to observe during a traditional PCT examination (Figure 3). 5) adapter for trial lenses, (6) LCD shutters, (7) hot mirror, (8) drive system allowing the optics to be adjusted to the user's pupillary distance, (9) NIR LED illuminator, (10) movable fixing element for optical components, (11) fixation point for the non-fixing eye, (12) fixation point for the fixing eye. The pupil distance can be set from 53 to 82 mm and is taken into account when setting the following fixation point positions on the test screen, increasing the reliability of the results in both children and adults.…”
Section: Construction Of the Devicementioning
confidence: 99%
“…A highly detailed image of the pupil is obtained, which enables an algorithm to detect adjusting movements of less than 0.2 mm, difficult to observe during a traditional PCT examination (Figure 3). 5) adapter for trial lenses, (6) LCD shutters, (7) hot mirror, (8) drive system allowing the optics to be adjusted to the user's pupillary distance, (9) NIR LED illuminator, (10) movable fixing element for optical components, (11) fixation point for the non-fixing eye, (12) fixation point for the fixing eye. 5) adapter for trial lenses, (6) LCD shutters, (7) hot mirror, (8) drive system allowing the optics to be adjusted to the user's pupillary distance, (9) NIR LED illuminator, (10) movable fixing element for optical components, (11) fixation point for the non-fixing eye, (12) fixation point for the fixing eye.…”
Section: Fundamentals Of Measurement Techniquesmentioning
confidence: 99%
See 2 more Smart Citations