“…In the following failure analysis, the predicted failure loads were determined based on either G Ic , G IIc , or G Tc , where G Tc G Ic G IIc . To demonstrate the effectiveness of the present model, the failure loads predicted by the present model were compared with the failure loads predicted by the previous analytical model [5], which assumes a thin bondline with uniform adhesive stresses throughout the adhesive thickness. The same method used to determine the G Ic and G IIc by the present model was used with the previous analytical model to obtain the G Ic and G IIc used for the failure load prediction by the previous model, where G Ic 0:32 kJ=m 2 and G IIc 0:53 kJ=m 2 were used for the T300/E765 (C/Ep) laminate and G Ic 0:95 kJ=m 2 and G IIc 0:62 kJ=m 2 were used for the 7781/E765 (Gl/Ep) laminate.…”