Strategic Reduction of Area and Power in FIR Filter Architecture for ECG Signal Acquisition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
29
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(29 citation statements)
references
References 28 publications
0
29
0
Order By: Relevance
“…Various FIR filter architectures have been developed by researchers to address the issues related to FIR filter design [1][2][3][4], the major huddle in the design of FIR filter is the multiplier unit [5], as the FIR filter needs higher order for near ideal response and hence the computational complexity increases, thereby the number of multipliers required also increases [1,14]. Multiplication is one of the fundamental operations in all DSP applications therefore extra care is to be taken while designing the FIR filter [3,10].…”
Section: Related Workmentioning
confidence: 99%
See 2 more Smart Citations
“…Various FIR filter architectures have been developed by researchers to address the issues related to FIR filter design [1][2][3][4], the major huddle in the design of FIR filter is the multiplier unit [5], as the FIR filter needs higher order for near ideal response and hence the computational complexity increases, thereby the number of multipliers required also increases [1,14]. Multiplication is one of the fundamental operations in all DSP applications therefore extra care is to be taken while designing the FIR filter [3,10].…”
Section: Related Workmentioning
confidence: 99%
“…[4] as compared in case studies 1 -3. The reduction in area metric is observed as dipping in the slice requirement by 31%, 47%, and 110% and dipping in the LUT requirement by 58%, 66%, and 65%, further, the delay metric is improved by 49%, 80%, and 67% when compared with MIMO-based parallel architecture of [1] on the same platforms suggested in [2][3][4] respectively.…”
mentioning
confidence: 94%
See 1 more Smart Citation
“…5 Such devices are often battery-operated and need to be compact, imposing tight constraints on the area and power consumption of all the sub-system blocks. 6 An ECG wave during a typical cardiac cycle along with the features is shown in Figure 1. As observed from Figure 1, the ECG signals contain a lot of pathological and physiological information which can be interpreted only by the study of its morphological and interval features.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, in recent times, interest has grown for out‐of‐the‐hospital continuous ECG monitoring devices 5 . Such devices are often battery‐operated and need to be compact, imposing tight constraints on the area and power consumption of all the sub‐system blocks 6 …”
Section: Introductionmentioning
confidence: 99%