Abstract: This paper presents the findings of an experimental investigation undertaken to evaluate the influence of externally bonded CFRP laminates on the punching shear capacity of a two-way spanning slab-column connection. Two control and five strengthened RC slabs were prepared and tested under concentrated load. The variables of the experiment were the anchorage type and width of the CFRP plates used. The structural response of the samples in terms of load, deflection, strain and cracking was monitored and analysed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 9 publications
0
15
0
Order By: Relevance
“…Brittle in behavior, it exhibits a unique tensile strength higher than steel with their weight equal to one-quarter of steel [13]. Field applications have shown excellent performance and durability of FRP retrofitted structures [14][15][16][17][18][19][20][21][22][23][24][25]. FRP strips were bonded "On Grooves" (EBROG) and "In Grooves" (EBRIG).…”
Section: Introductionmentioning
confidence: 99%
“…Brittle in behavior, it exhibits a unique tensile strength higher than steel with their weight equal to one-quarter of steel [13]. Field applications have shown excellent performance and durability of FRP retrofitted structures [14][15][16][17][18][19][20][21][22][23][24][25]. FRP strips were bonded "On Grooves" (EBROG) and "In Grooves" (EBRIG).…”
Section: Introductionmentioning
confidence: 99%
“…The ordinary failure for applying the external strengthening technique was the hasty decrypting of CFRP. Decrypting could be delayed developing the structural attitude of strengthened connection via supplying a final berth to the external connected FRP [11]. Post-installation of CFRP shear bolts, as shear strengthening, in penetrated holes were stuffed with suitable epoxy cement.…”
Section: Strengthening Of Flat Slabs Connection With Edge Columns Against Punching Shear Using Near Surface Mounted (Nsm) Carbon Fiber Rementioning
confidence: 99%
“…This strengthening method increases the flexural reinforcement and therefore increases the punching shear strength by delaying the shear cracks formation. The common failure for external strengthening technique is the premature debonding of FRP, which could be delayed and improve the structural behavior of strengthened connection by providing end anchorage to the externally bonded FRP [5].Post-installation of FRP studs or FRP shear dowels, as shear reinforcement, in drilled holes filled with suitable epoxy grout falls into internal strengthened method for slab-columns connections. The drilled holes, to insert shear reinforcement, in the critical punching shear area of the slab near the column could further damage the degenerated slab.…”
Section: Introductionmentioning
confidence: 99%