Strengths and limitations of molecular subtyping in a community outbreak of Legionnaires' disease

Abstract: An epidemiological and microbiological investigation of a cluster of eight cases of Legionnaires' disease in Los Angeles County in November 1997 yielded conflicting results. The epidemiological part of the investigation implicated one of several mobile cooling towers used by a film studio in the centre of the outbreak area. However, water sampled from these cooling towers contained L. pneumophila serogroup 1 of another subtype than the strain that was recovered from case-patients in the outbreak. Samples from … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
16
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(16 citation statements)
references
References 12 publications
0
16
0
Order By: Relevance
“…The purpose was to relate the plumes for each source to the patients' residences and not to estimate the actual concentration level. The identification of the same Legionella genotype from patient samples and the air scrubber but from no other potential source was strong evidence of the involvement of company F. However, it has been reported elsewhere that cooling towers located close to each other may harbor the same Legionella genotype [22]. The microbiological results thus need to be interpreted together with results from the epidemiological and environmental investigation.…”
Section: Discussionmentioning
confidence: 90%
“…The purpose was to relate the plumes for each source to the patients' residences and not to estimate the actual concentration level. The identification of the same Legionella genotype from patient samples and the air scrubber but from no other potential source was strong evidence of the involvement of company F. However, it has been reported elsewhere that cooling towers located close to each other may harbor the same Legionella genotype [22]. The microbiological results thus need to be interpreted together with results from the epidemiological and environmental investigation.…”
Section: Discussionmentioning
confidence: 90%
“…Even so, caution must be used when interpreting results of subtyping for the identification of an outbreak reservoir. A recent study determined that strains isolated from non-outbreak-related sources were identical to the clinical isolates by four subtyping procedures (AP-PCR, PFGE, monoclonal antibody, and multilocus enzyme electrophoresis) (171). Amplified fragment length polymorphism (AFLP) represents the current state-of-the-art subtyping procedure (274).…”
Section: Subtyping Of Legionella Sppmentioning
confidence: 99%
“…In Bloomington, U.S.A, for example [10], a dispersed outbreak was contained by shock dosing only one tower. Two outbreaks stopped although no control measures were performed [11,12], and one outbreak stopped before completion of the decontamination of towers [13]. An outbreak of Legionnaires' disease occurred in 1988 in Bolton, England, with 37 cases of pneumonic disease and 23 which were classified as non-pneumonic.…”
Section: Discussionmentioning
confidence: 99%