2006
DOI: 10.1007/s00167-006-0181-z
|View full text |Cite
|
Sign up to set email alerts
|

Stress fractures of the femur after ACL reconstruction with transfemoral fixation

Abstract: The ACL reconstruction with hamstring tendons has become increasingly popular, in part because it is assumed that the complication rate associated with the technique and their severity are lower than with patellar tendon. Two cases of stress reaction of the medial supracondylar area of the femur after ACL reconstruction with hamstring tendons using BioTransfix (Arthrex, Naples, FL, USA) devices for fixation within femur are presented. Both patients were professional athletes (one soccer and one basketball play… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
16
0
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 9 publications
0
16
0
1
Order By: Relevance
“…3,22 Stress fracture of the medial supracondylar area of the femur after ACL reconstruction with hamstring tendons using transfemoral fixation in professional athletes has been reported previously. 1 However, there have been no reported cases of complete periprosthetic fracture along the tract created by the guide pin during transfemoral graft fixation. The fixation device is impacted into the lateral cortex to avoid prominence and soft-tissue irritation.…”
Section: Discussionmentioning
confidence: 99%
“…3,22 Stress fracture of the medial supracondylar area of the femur after ACL reconstruction with hamstring tendons using transfemoral fixation in professional athletes has been reported previously. 1 However, there have been no reported cases of complete periprosthetic fracture along the tract created by the guide pin during transfemoral graft fixation. The fixation device is impacted into the lateral cortex to avoid prominence and soft-tissue irritation.…”
Section: Discussionmentioning
confidence: 99%
“…Both devices require their own respective insertion techniques and apart from missing the femoral tunnel altogether during graft placement which can occur with both devices, other devicespecific complications have occurred with the Transfix device during insertion such as broken or twisted graft-passing wires [12][13][14] . Supracondylar femur fractures have been described with the use of Transfix too though this was not encountered in our study 15,16 . We had one patient which had a broken Transfix pin which presented as subcutaneous swelling necessitating surgical removal.…”
Section: Discussionmentioning
confidence: 51%
“… 11 Although biomechanical testing demonstrated equivalent to superior results compared with interference screw fixation, 1 various complications have also been reported. These include implant breakage, 10 intra-articular protrusion, 23 and stress fractures of the femur 5 among others. Secondary to these concerns, the use of suspensory cortical fixation has dramatically increased over the past 5 years.…”
Section: Discussionmentioning
confidence: 99%
“… 1 However, there have been numerous complications associated with its use, including implant breakage with subsequent graft laxity 10 and lateral meniscal tearing, 12 intra-articular protrusion, 23 iliotibial band friction syndrome, 24 medial-sided pin prominence, 22 and stress fractures of the femur. 5 In light of these concerns, suspensory cortical fixation was developed and has been consequently adopted by many surgeons due to its ease of use. Nevertheless, increased tunnel widening with suspensory as compared with cross-pin fixation has been noted, 6 , 9 resulting in graft loosening with 2 to 3 mm of motion during physiologic loads.…”
mentioning
confidence: 99%