2007
DOI: 10.1016/j.surfcoat.2006.07.178
|View full text |Cite
|
Sign up to set email alerts
|

Structural and tribological properties of the plasma nitrided Ti-alloy biomaterials: Influence of the treatment temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
37
0
9

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(51 citation statements)
references
References 19 publications
5
37
0
9
Order By: Relevance
“…High resolution scans were then used to obtain information regarding the surface chemical state of the materials. [19]. The formation of oxynitride layers on Ti with gas diffusion treatment has been also reported [20].…”
Section: Resultsmentioning
confidence: 85%
See 1 more Smart Citation
“…High resolution scans were then used to obtain information regarding the surface chemical state of the materials. [19]. The formation of oxynitride layers on Ti with gas diffusion treatment has been also reported [20].…”
Section: Resultsmentioning
confidence: 85%
“…Among them, nitriding processes based on the thermo-diffusion mechanism have been used to improve the corrosion and wear resistance properties as well as bioactivity of Ti and Ti-based alloys, resulting from the formation of Ti nitrides. Conventional nitriding processes have several disadvantages, however, such as long processing times, poor surface finish, poor control of the nitride layer formation etc [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…When standard processes such as gas or plasma nitriding are carried out on titanium, the wear resistance is improved due to the formation of a hard nitrogen compound layer [3]. However, the fatigue strength of nitrided titanium is reduced due to brittleness of the nitrogen compound layer [4].…”
Section: Introductionmentioning
confidence: 99%
“…Conventional nitriding processes have several disadvantages, however, such as long processing times, poor surface finish, poor control of the nitrided layer formation etc. [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, a comparatively high operating pressure can increase the possibility of surface contamination and also retard the diffusion of nitrogen [11][12][13], which produces a very thin nitrided layer (0.1-0.2 μm) even after a long treatment time. This is neither economical nor favorable for biomedical applications [11,13]. Recently, laser nitriding has been viewed as attractive in comparison to other nitriding processes due to its short treatment time and accuracy in controlling the treatment location.…”
Section: Introductionmentioning
confidence: 99%