2016
DOI: 10.3233/fde-160049
|View full text |Cite
|
Sign up to set email alerts
|

Structural performance of GFRP connectors in composite sandwich facade elements

Abstract: A systematic testing and modelling program has been developed for the verification of the structural performance of facade sandwich elements to take structural aspects into consideration in the SESBE research project, focusing on the development of "smart" facade elements. The present paper mainly focuses on the verification of the mechanical performance of the glass fibre reinforced polymer (GFRP) connectors of the novel type of facade element composed of reactive powder concrete (RPC) panels with foam concre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 2 publications
0
12
0
Order By: Relevance
“…The material development has been presented elsewhere for RPC [11,20], FC [25], GFRP [22] and TRRPC [21]. The component testing and modelling related to connector local failure and shear tests can be found in [24], and that concerning the four-point bending tests in [22]. Based on preliminary structural investigations in the conceptual phase, a thorough testing and modelling program was defined, as per Figure 2, to enable the verification of the structural performance of the elements at different phases, namely material development, component modelling and testing.…”
Section: Anchorage Systemmentioning
confidence: 99%
See 4 more Smart Citations
“…The material development has been presented elsewhere for RPC [11,20], FC [25], GFRP [22] and TRRPC [21]. The component testing and modelling related to connector local failure and shear tests can be found in [24], and that concerning the four-point bending tests in [22]. Based on preliminary structural investigations in the conceptual phase, a thorough testing and modelling program was defined, as per Figure 2, to enable the verification of the structural performance of the elements at different phases, namely material development, component modelling and testing.…”
Section: Anchorage Systemmentioning
confidence: 99%
“…A double connector is composed of two single connectors mirrored with respect to the longitudinal direction and fastened at intersecting points using plastic tie straps. The connector performance in an element was previously investigated via modelling and testing on a component level [22,24]. As a result, the diagonal bars were observed to be primarily loaded by axial tensile and compressive forces, as illustrated in Figure 4b.…”
Section: Glass Fibre Reinforced Polymer (Gfrp) Connectorsmentioning
confidence: 99%
See 3 more Smart Citations