2006
DOI: 10.3130/jaabe.5.153
|View full text |Cite
|
Sign up to set email alerts
|

Structural Performance of Steel-Concrete Composite Column Subjected to Axial and Flexural Loading

Abstract: The steel-concrete composite column is a new composite member that can achieve constructability and economy by fi lling the empty space in the steel H-fl ange with concrete. Even before this study was conducted, it had been proven in another study on the axial capacity of a steel-concrete composite column that the steel-concrete composite column with a non-compact section has excellent structural strength. Further studies on fl exural-compressive capacity are necessary, though, due to the structural characteri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0
5

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 15 publications
0
3
0
5
Order By: Relevance
“…More recently, the experimental and analytical research was carried out on PEC columns subjected to eccentrically axial load or flexural load (e.g. Brent et al, 2006;Oh et al, 2006;Zhao et al, 2007;Mahbuba et al, 2007). However, there are still some unclear aspects remained.…”
Section: Introductionmentioning
confidence: 99%
“…More recently, the experimental and analytical research was carried out on PEC columns subjected to eccentrically axial load or flexural load (e.g. Brent et al, 2006;Oh et al, 2006;Zhao et al, 2007;Mahbuba et al, 2007). However, there are still some unclear aspects remained.…”
Section: Introductionmentioning
confidence: 99%
“…이러한 콘크리트의 조기압괴로 인하여, SRC기둥에 대한 기존의 실험연구 [2], [3], [4], [5], [6], [7] 에서는 적용된 재료의 강도 에 한계가 있었다 (Fig. 2, 강재 항복강도   ≤ 499MPa, 콘크리트 압축강도   ≤ 91MPa).…”
unclassified
“…e Chicoine, Massicote e Tremblay (2003) estudaram apenas o comportamento do pilar quando solicitado a esforços de compressão centrada. Já Oh et al (2006) se preocuparam em avaliar os pilares submetidos a esforços de compressão e flexão simultâneos. Para isto, quatro pilares mistos foram ensaiados utilizando um atuador para aplicar uma força axial e outros dois atuadores para gerar uma dupla curvatura.…”
Section: Seções Formadas Por Chapas Esbeltas De Açounclassified
“…Finalmente, os resultados experimentais demonstraram que o cálculo do fator k produz bons resultados. O programa experimental realizado porOh et. al (2006) e composto por pilares mistos parcialmente revestidos formados por perfis metálicos não compactos foi apresentado no item 2.4 do Capítulo 2.…”
unclassified
See 1 more Smart Citation