2014
DOI: 10.1016/j.enconman.2013.10.011
|View full text |Cite
|
Sign up to set email alerts
|

Structural vulnerability in transmission systems: Cases of Colombia and Spain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
6

Year Published

2014
2014
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 21 publications
0
9
0
6
Order By: Relevance
“…We use the geodesic vulnerability index ( ν) and impact on connectivity (S) to measure the functionality of the combined electric power and gas network, with respect to the stable condition, when the functionality of a node is compromised. These indexes have been applied to both IEEE test networks and actual electrical networks [26,27]. Although the potential of these indexes has been shown in electrical networks, they have not been applied in coupled networks, which is the goal of this work.…”
Section: Measures Of Vulnerability In Networkmentioning
confidence: 99%
“…We use the geodesic vulnerability index ( ν) and impact on connectivity (S) to measure the functionality of the combined electric power and gas network, with respect to the stable condition, when the functionality of a node is compromised. These indexes have been applied to both IEEE test networks and actual electrical networks [26,27]. Although the potential of these indexes has been shown in electrical networks, they have not been applied in coupled networks, which is the goal of this work.…”
Section: Measures Of Vulnerability In Networkmentioning
confidence: 99%
“…Important variables, such as voltage, power, efficiency, and state of charge (SOC) during charging (P B(b,t) > 0) and discharging (P B(b,t) ≤ 0) conditions have been estimated. Definitions of battery voltage, efficiency, and SOC are shown in (28), (29), and (30), respectively, while some of their operating constraints are presented in (31) and (32). Calculation of battery voltage during charging and discharging is explained in (33) and (34), respectively.…”
Section: Model Of Distributed Bessmentioning
confidence: 99%
“…In this subsection, the vulnerability [32] of MG configuration of Figure 4 is analysed. Specifically, CIs shown in Figures 9 and 11 have been used to evaluate the vulnerability of the whole system against contingencies intentionally created (CIC) on the renewable and CG subsystems, respectively.…”
Section: Vulnerability Assessment Of Autonomous Mgmentioning
confidence: 99%
“…En el caso español, por ejemplo, la red de transporte suma más de 50.000 Km de líneas eléctricas, pero las redes de distribución superan los 500.000 Km [38]. Es importante tener presente que la tarea de protección de estas infraestructuras tan extensas y numerosas debe realizarse en la medida que sea viable técnica y económicamente.…”
Section: Cadena De Valor De Infraestructuras Eléctricasunclassified