1990
DOI: 10.1021/ja00180a001
|View full text |Cite
|
Sign up to set email alerts
|

Structure of an intermediate of coenzyme B12 catalysis by EXAFS: Co2+ B12

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
43
0

Year Published

1992
1992
2017
2017

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 49 publications
(46 citation statements)
references
References 1 publication
3
43
0
Order By: Relevance
“…Fitting these data to models can define the extent to which the zinc sites resemble one another. We measured the distances and Debye-Waller factors of these scatterers by Fourier filtering, back-transforming, and nonlinear least-squares fitting of the peptide and virus data to the models (19,(27)(28)(29). The observed truncation artifacts are minimized by matching the window functions of the model compounds and the unknowns.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Fitting these data to models can define the extent to which the zinc sites resemble one another. We measured the distances and Debye-Waller factors of these scatterers by Fourier filtering, back-transforming, and nonlinear least-squares fitting of the peptide and virus data to the models (19,(27)(28)(29). The observed truncation artifacts are minimized by matching the window functions of the model compounds and the unknowns.…”
Section: Resultsmentioning
confidence: 99%
“…The distance errors are estimated by a number of methods described previously (19,28). Variations in the individual Zn-S distances are not resolved by this procedure; data ofthis k range are unable to resolve contributions that are separated by -O.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Ge detector was run at internal count rates of 40,000 counts channel-' s-l to minimize dead time losses. Data for EIAV and MMTV samples were collected at 170 K using a liquid nitrogen cryostat to limit sample damage and to minimize the thermal component of Debye-Waller factors (which leads to maximum differences in backscattering for chemically distinct ligands) (Sagi et al, 1990).…”
Section: Exafs Data Collection and Processingmentioning
confidence: 99%
“…The Co K-edge E 0 of pristine B12 is 7724.5 eV, which value declines as the pyrolysis temperature increases. In previous studies, the Co oxidation state of pristine B12 was 3þ [25,26]. Scheuring et al used timeresolved X-ray absorption spectroscopy to study pristine B12-Co(III) and base-off B12-Co(II), and found that the E 0 of Co (II) was lower than that of Co(III) by approximately 4.0e6.0 eV [27].…”
Section: Structure Analysismentioning
confidence: 99%