2021
DOI: 10.1088/1748-0221/16/01/p01038
|View full text |Cite
|
Sign up to set email alerts
|

Studies on charging-up of single Gas Electron Multiplier

Abstract: Mechanisms of charging-up and charging-down of Gas Electron Multiplier (GEM) have been studied. Experimental investigations have been carried out on both dielectric polarization and radiation charging of GEMs.Environmental parameters, such as pressure and temperature have been monitored to normalize their effects on the charging-up and charging-down measurements. Variation in gain due to the combined effects of the mentioned parameters, as well as in isolation, has been illustrated.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 18 publications
1
11
0
Order By: Relevance
“…Further R&D in this direction is in progress and some preliminary test results will be reported here. Several other R&D projects are also underway to explore the possibility of using Gaseous Electron Multiplier (GEM)-based detectors as the muon tracker [6]. In the following, a comprehensive report about the numerical work along with the instrumentation carried out by us for the R&D of the proposed MST setup will be furnished.…”
Section: Herementioning
confidence: 99%
See 1 more Smart Citation
“…Further R&D in this direction is in progress and some preliminary test results will be reported here. Several other R&D projects are also underway to explore the possibility of using Gaseous Electron Multiplier (GEM)-based detectors as the muon tracker [6]. In the following, a comprehensive report about the numerical work along with the instrumentation carried out by us for the R&D of the proposed MST setup will be furnished.…”
Section: Herementioning
confidence: 99%
“…Several research activities carried out to study and optimize their design parameters for efficient operation in connection to other experiments [12] have been utilized in the R&D. An effort has been put to explore environment-friendly gas mixture to operate the RPCs which should be relevant for the R&D of the MST setup too [13]. There have been several experimental and numerical activities performed to understand the functioning of GEM-based detectors [6] which are relevant for this R&D activity.…”
Section: Experimental Measurementsmentioning
confidence: 99%
“…The gain calibration has been done using the current measurement from the picoammeter and energy spectra from Multi-Channel Analyzer (MCA). More details about the experimental setup, radiation rate and gain measurement are mentioned in [3].…”
Section: Setupmentioning
confidence: 99%
“…As a result, the charging-up plays an important role in GEM detector functioning. A detailed analysis of charging-up and its effects on gain for a single GEM have been decribed in [9], with detailed investigation of charging-up with various field and rate configurations. The work also includes gain measurment technique and methodology for varying radiation rates with help of collimator while using extended radiation source.…”
Section: Introductionmentioning
confidence: 99%
“…The studies carried out on a single GEM in [9] was necessary to understand the basic features of the complex process that has been achieved with a reasonable amount of success. However, in real experiments, single GEM configurations are rarely used, if at all.…”
Section: Introductionmentioning