2020
DOI: 10.1177/0954408920936799
|View full text |Cite
|
Sign up to set email alerts
|

Studies on corrosion behavior of AISI 316L cold metal transfer weldments in physiological solutions

Abstract: Evaluating the mechanical integrity and corrosion performance of welded joints is vital to replace the malfunctioning parts in human body. This research aims to study the effect of Cold Metal Transfer (CMT) process on the corrosion behavior of austenitic stainless steel (AISI 316L) weldments in physiological solution. ER316L filler wire is used to weld thin sheets of 2mm to butt joint configuration. Optical microscopy and Scanning electron microscopy (SEM) are used to study the microstructural evolution in bas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 46 publications
(50 reference statements)
0
5
0
Order By: Relevance
“…Pitting resistance was higher on the ER-308L overlay due to the presence of rich δ-ferrite content (4.21 FN). [48][49][50] Therefore, a constant and efficient Cr-rich passive film formation is revealed in the anodic polarization.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Pitting resistance was higher on the ER-308L overlay due to the presence of rich δ-ferrite content (4.21 FN). [48][49][50] Therefore, a constant and efficient Cr-rich passive film formation is revealed in the anodic polarization.…”
Section: Resultsmentioning
confidence: 99%
“…57 The pitting resistance is not significantly affected when the FN is less than 8% in ASS welds or overlays. 18,38,49,58,59 Conclusion ER-308L weld overlays were successfully deposited by the Robotic-GMAW process to examine the microstructural characteristics and corrosive behaviour. The conclusion of the study is as follows:…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The stainless steel 316L substrate microstructure is mainly of equiaxed grains with annealing twins, Figure 2a. Microstructure was mainly austenitic with some fraction of ferrite [21]. Ferrite number of stainless steel 316L substrate was 0.5 measured with the aid of feritscope.…”
Section: Resultsmentioning
confidence: 99%
“…The decrease in ductility and an increase in tensile strength indicates an increase in the amount of δ -ferrite. 22,23 The bend sample is prepared according to ASTM E190-92. The results (refer Supplementary Figure 2(a)) show the DS-GTA weld specimen after the bending test.…”
Section: Resultsmentioning
confidence: 99%