2016
DOI: 10.1364/ao.55.002800
|View full text |Cite
|
Sign up to set email alerts
|

Studies on design of 351  nm focal plane diagnostic system prototype and focusing characteristic of SGII-upgraded facility at half achievable energy performance

Abstract: In order to obtain the intensity distribution of a 351 nm focal spot and smoothing by spectral dispersion (SSD) focal plane profile of a SGII-upgraded facility, a type of off-axis imaging system with three spherical mirrors, suitable for a finite distance source point to be imaged near the diffraction limit has been designed. The quality factor of the image system is 1.6 times of the diffraction limit tested by a 1053 nm point source. Because of the absence of a 351 nm point source, we can use a Collins diffra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…As the pulse again propagates through the power amplifier, after passing the TSF and transport mirrors, it enters the final optics assembly (FOA) [50] and it is frequency converted to 351 nm light, before being focused to the target chamber using the wedged focus lens. In addition, the measurement system [51][52][53] , centralized control system [54,55] , and automatic alignment system [56,57] are all involved to enable the effective operation of the facility.…”
Section: Sg-ii Up Nanosecond Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…As the pulse again propagates through the power amplifier, after passing the TSF and transport mirrors, it enters the final optics assembly (FOA) [50] and it is frequency converted to 351 nm light, before being focused to the target chamber using the wedged focus lens. In addition, the measurement system [51][52][53] , centralized control system [54,55] , and automatic alignment system [56,57] are all involved to enable the effective operation of the facility.…”
Section: Sg-ii Up Nanosecond Systemmentioning
confidence: 99%
“…The total output energy of eight beams is in routine operation. We have developed a precision diagnostic system (PDS) based on a type of off-axis imaging system with three spherical mirrors [52] to measure the key parameters, such as the near and far fields. The near and far fields with a frequency and energy of 8.5 kJ are shown in Figure 11.…”
Section: Performance Of the Sg-ii Up Facilitymentioning
confidence: 99%