Studies on the use of filter-based IR detector for short-chain branching characterization of polyolefin copolymers with high temperature size exclusion chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(21 citation statements)
references
References 24 publications
2
19
0
Order By: Relevance
“…The IR-5 provides a more robust concentration detector with less sensitivity to pressure and temperature changes compared to a DRI detector, and it can also be used for determination of comonomer content across the MWD. An evaluation of two different IR-5 detectors on two different HT-GPC instruments was recently reported . It was found that TCB is not completely transparent in the IR-5 detector wavelength range, so the IR absorbance from the sample can be overwhelmed by very strong background absorbance from the solvent.…”
Section: Size-based Separations Of Synthetic Polymersmentioning
confidence: 99%
See 3 more Smart Citations
“…The IR-5 provides a more robust concentration detector with less sensitivity to pressure and temperature changes compared to a DRI detector, and it can also be used for determination of comonomer content across the MWD. An evaluation of two different IR-5 detectors on two different HT-GPC instruments was recently reported . It was found that TCB is not completely transparent in the IR-5 detector wavelength range, so the IR absorbance from the sample can be overwhelmed by very strong background absorbance from the solvent.…”
Section: Size-based Separations Of Synthetic Polymersmentioning
confidence: 99%
“…For nonpropylene copolymers having less than 70 methyl groups per 1000 carbon atoms, a single linear composition calibration was obtained. For propylene-based copolymers, a nonlinear calibration was needed . In another example of composition-based detection, isotopic labeling via the deuterium exchange process was developed successfully for polyethylene, isotactic and syndiotactic polypropylene and was monitored by HT-GPC coupled to IR-5 .…”
Section: Size-based Separations Of Synthetic Polymersmentioning
confidence: 99%
See 2 more Smart Citations
“…An in‐depth research on the quantitative aspects was recently published by Frijns‐Bruls et al. [121]. Recently, Beskers et al.…”
Section: Detectors In Polymer Lc and Their Strengths And Weaknessesmentioning
confidence: 99%