Study and Application of Micrometric Alignment on the Prototype Girders of the CLIC Two-Beam Module

Abstract: The Compact LInear Collider (CLIC), currently under study at CERN, aims at the development of a Multi-TeV e + e -collider. The micro-precision CLIC RF-structures will have an accelerating gradient of 100 MV/m and will be mounted and aligned on specially developed supporting girders. The girder fabrication constraints are dictated by stringent physics requirements. The micrometric pre-alignment over several kilometers of girders, allow for the CLIC structures to fulfill their acceleration and collision function… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…The MB of the module Type-0 contains only Accelerating Structures whereas the modules of Type-1 up to Type-4 include also MB-quadrupoles of variable length. The MBquadrupoles take the place of two (2), four (4), six (6) or eight (8) Accelerating Structures (AS), respectively [3].…”
Section: Clic Layout and Componentsmentioning
confidence: 99%
See 1 more Smart Citation
“…The MB of the module Type-0 contains only Accelerating Structures whereas the modules of Type-1 up to Type-4 include also MB-quadrupoles of variable length. The MBquadrupoles take the place of two (2), four (4), six (6) or eight (8) Accelerating Structures (AS), respectively [3].…”
Section: Clic Layout and Componentsmentioning
confidence: 99%
“…The module length is presently 2010 mm dictated by the mechanical and thermal stability of the overall system, along with several other technical parameters. The length of 30 mm is reserved for the inter-girder connection, which is referred to as Articulation Point [6]. The module supporting system is mechanically articulated throughout the entire length of the DB linac.…”
Section: Clic Layout and Componentsmentioning
confidence: 99%
“…The MB of the module Type-0 contains only Accelerating Structures whereas the modules of Type-1 up to Type-4 include also MB-quadrupoles of variable length. The MBquadrupoles take the place of two (2), four (4), six (6) or eight (8) Accelerating Structures (AS), respectively [3].…”
Section: Clic Layout and Componentsmentioning
confidence: 99%