2021
DOI: 10.1016/j.seta.2021.101149
|View full text |Cite
|
Sign up to set email alerts
|

Study of a common control strategy for grid-connected shunt active photovoltaic filter without DC/DC converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…The grid active and reactive powers (p g and q g ) can be expressed in the abc-frame as follows [6]:…”
Section: Grid Connected Four-leg Pwm Vsi Modeling In Dq0-frame Based ...mentioning
confidence: 99%
See 1 more Smart Citation
“…The grid active and reactive powers (p g and q g ) can be expressed in the abc-frame as follows [6]:…”
Section: Grid Connected Four-leg Pwm Vsi Modeling In Dq0-frame Based ...mentioning
confidence: 99%
“…For this purpose, considerable attention and challenge is directed towards renewable energy resources (RER) that are inexhaustible and spotless, including solar and wind energy technology [2,3]. Because of its high reliability, efficiency, low total harmonic distortion (THD), fast dynamics, high-power applications, and bidirectional power flow, the three-phase three-leg PWM voltage source inverter (VSI) is the key device and the most common choice for interfacing, controlling, and delivering renewable energy [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…In [20], SMT was proposed for 3 modules, ACHB-MLI with two DC voltages configurations to generate 19, 27 voltage levels, respectively. These configurations use ratios of [1:2:6] and [1:3:9], where the second one corresponds to the independent DC voltages of [24,48,144] V. In order to motivate the choice of the number of ACHB modules associated with the SMT algorithm, a complementary study, via-a-vis the literature, is made in this research. In this context, a comparison between 3-and 4modules SMT-SCHB structure supplying/driving a low voltage sensitive load, for instance asynchronous motor, is made as presented in Table . 1.…”
Section: ) Achb-mli Based On the Smtmentioning
confidence: 99%
“…The equivalent capacitance selection for each CHB module will correspond to the industrial demand. In this context, the following expression is derived and adapted to our study [24]:…”
Section: D-dc-link Capacitors Rating Selectionmentioning
confidence: 99%
“…For the DC bus voltage control, the use of a proportional-integral controller, as shown in Figure 1 , is proposed. Then, neglecting the switching losses in the inverter, the relation between the regulating power and the capacitor voltage can be written as follows [ 28 ]: …”
Section: State Of the Art Of Lcl/saf Structure Controllersmentioning
confidence: 99%