2016 International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM) 2016
DOI: 10.1109/issimm.2016.7803713
|View full text |Cite
|
Sign up to set email alerts
|

Study of precision constant current sources with resistor load and a cole-cole load for multi-frequency in electrical impedance tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…The analysis of the literature and technical documentation showed the existence of two basic types of circuit configurations that work with floating or grounded load. In previous works, [5][6][7][8][9][10][11][12][13][14] different circuits of voltage-to-current converters with grounded load are presented, in which various useful structural modifications and frequency compensations with external passive components are proposed for improving the stability in a given frequency range, as well as increasing the value of the output resistance. Moreover, the majority of the electronic circuits [3][4][5][6][8][9][10][11][12]14 are based on the Improved Howland Current Pump, which uses one op-amp and five (or six) resistors.…”
Section: Introductionmentioning
confidence: 99%
“…The analysis of the literature and technical documentation showed the existence of two basic types of circuit configurations that work with floating or grounded load. In previous works, [5][6][7][8][9][10][11][12][13][14] different circuits of voltage-to-current converters with grounded load are presented, in which various useful structural modifications and frequency compensations with external passive components are proposed for improving the stability in a given frequency range, as well as increasing the value of the output resistance. Moreover, the majority of the electronic circuits [3][4][5][6][8][9][10][11][12]14 are based on the Improved Howland Current Pump, which uses one op-amp and five (or six) resistors.…”
Section: Introductionmentioning
confidence: 99%
“…Electrical Impedance Tomography (EIT) is an imaging technique and radiation-free that uses electrical signals to reconstruct an image from the human body's conductivity distribution information. EIT is a promising technique that has been used in various fields such as industry, geophysics, and medical application [1][2][3][4][5][6][7][8]. This imaging technique is an imaging technique that has advantages compared to other imaging techniques.…”
Section: Introductionmentioning
confidence: 99%
“…The influence of current frequency tends to affect the capability of current can pass through the medium. In study of cola cole load, it said that low frequency had a lower capability to pass the medium than high frequency [6].…”
Section: Introductionmentioning
confidence: 99%