1958
DOI: 10.1103/physrev.112.103
|View full text |Cite
|
Sign up to set email alerts
|

Study of Reactor-Irradiatedα-Al2O

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0
1

Year Published

1961
1961
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 57 publications
(9 citation statements)
references
References 6 publications
1
7
0
1
Order By: Relevance
“…It is interesting to note that the result just arrived at is essentially the same as calculated for absorption by three-phonon processes, 6,12 in which acoustic phonons are absorbed in collisions with thermal phonons. Such a collision process requires conservation of momentum, such that the momenta of the thermal and acoustic phonon before the collision must be equal to the momentum of the thermal phonon after collision.…”
Section: A Acoustic Absorption By Synchronous Thermal Phononssupporting
confidence: 63%
See 3 more Smart Citations
“…It is interesting to note that the result just arrived at is essentially the same as calculated for absorption by three-phonon processes, 6,12 in which acoustic phonons are absorbed in collisions with thermal phonons. Such a collision process requires conservation of momentum, such that the momenta of the thermal and acoustic phonon before the collision must be equal to the momentum of the thermal phonon after collision.…”
Section: A Acoustic Absorption By Synchronous Thermal Phononssupporting
confidence: 63%
“…For the measurements on the Z-cut quartz, which is not piezoelectrically active, thin X-cut quartz disks were bonded to the end faces, or magnetic Permalloy films were evaporated on in order to excite sound by the magnetic-film technique. 9 6 The acoustic absorption could then be determined from the heights of the echo pulses. For various reasons, 10 such as misalignment of the two end faces, bulk inhomogeneity of the crystal, and diffraction effects, all of which do not vary with temperature, the echo pattern usually shows a sample-dependent nonexponential decay-even at the lowest temperatures.…”
Section: Experimental Partmentioning
confidence: 99%
See 2 more Smart Citations
“…The first scientific publication from a HIFAR neutron beam was from this instrument [7]. That paper in Nature states that the spectrometer was similar to that described by Antal and Goland [8]. The next instrument was the AAEC Crystal Spectrometer on the 4H2 hole, probably installed in late 1960 (It is shown as existing in Drawing AE8526 (8 December 1960)).…”
Section: The Early Years-1960-1975mentioning
confidence: 99%