2013
DOI: 10.1134/s1063780x13110068
|View full text |Cite
|
Sign up to set email alerts
|

Study of the azimuthal magnetic fields and scaling laws at the KPF-4-Phoenix facility

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0
3

Year Published

2014
2014
2017
2017

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 10 publications
0
11
0
3
Order By: Relevance
“…According to frame optical images, for typical PF-1000 experiments, the PCS height in the stage of radial compression is h z ~ 3-4 cm [8,23]. It is well known that the PCS has a finite radial thickness and consists of the regions of the shock wave and magnetic piston [8,[24][25][26][27]. In expression (10), by the effective current radius we mean the radial position of the infinitely thin layer in which the entire current of the compressed PCS flows.…”
Section: Technique For Calculating Some Electrotechnicalmentioning
confidence: 99%
See 1 more Smart Citation
“…According to frame optical images, for typical PF-1000 experiments, the PCS height in the stage of radial compression is h z ~ 3-4 cm [8,23]. It is well known that the PCS has a finite radial thickness and consists of the regions of the shock wave and magnetic piston [8,[24][25][26][27]. In expression (10), by the effective current radius we mean the radial position of the infinitely thin layer in which the entire current of the compressed PCS flows.…”
Section: Technique For Calculating Some Electrotechnicalmentioning
confidence: 99%
“…8221 with a lower neutron yield of 6.8 × 10 10 neutrons/shot. From the well-known expression for the skin depth under the assumption of the Spitzer conductivity [30], we can find the PCS electron temperature corresponding to the above estimate of the skin depth (as it was done in [27]…”
Section: Pf-1000 Experimentsmentioning
confidence: 99%
“…Для измерения параметров захваченных плазменными потоками магнитных по-лей использовалась магнитозондовая методика, разработанная для условий плазмофокусного разряда [17][18][19][20][21][22][23]. Конструкции магнитных зондов, адаптированных для измерений магнитных полей в плазменных потоках на установке ПФ-3, подробно описаны в работе [11].…”
Section: схема эксперимента и основные диагностические методыunclassified
“…Как следует из этого рисунка, скорость плазменного потока падает с ~(2,5-4)10 7 до ~(0,5-1,3)10 7 см/с по мере его продвижения из области пинчевания плазмы вдоль оси установки. Следует заметить, что аксиальная скорость движения, зарегистрированная на высоте 16 см над анодным электродом, оказывается выше, чем радиальная скорость финального сжатия ТПО v r ~ 210 7 см/с, полученная в работе [17] при тех же экспериментальных условиях с помощью магнитозондовых измерений.…”
Section: экспериментальные результатыunclassified
See 1 more Smart Citation