2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) 2012
DOI: 10.1109/nssmic.2012.6551985
|View full text |Cite
|
Sign up to set email alerts
|

Study of the capabilities of the Timepix detector for Ion Beam radiotherapy applications

Abstract: The finite range of ion beams in matter and the presence of the Bragg-peak at the end of their range enable to create highly localized dose distributions. This advantage represents at the same time a challenge -namely to control all factors influencing the dose distribution with high precision.To ensure the required quality of the dose distribution applied to the patient, a number of measurement procedures is conducted.Many of these techniques were adopted from photon beam radiotherapy. Improvements in terms o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…Timepix [1] was conceived as a timing measurement chip with an added functionality of measuring time-over-threshold (ToT). ToT functionality was found useful in many applications (for example [2,3]), and Timepix3 extends the functionality of Timepix by allowing simultaneous time-of-arrival (ToA)/ToT measurement. It also aims to improve the timing resolution of Timepix by over a factor of 6.…”
Section: Introductionmentioning
confidence: 99%
“…Timepix [1] was conceived as a timing measurement chip with an added functionality of measuring time-over-threshold (ToT). ToT functionality was found useful in many applications (for example [2,3]), and Timepix3 extends the functionality of Timepix by allowing simultaneous time-of-arrival (ToA)/ToT measurement. It also aims to improve the timing resolution of Timepix by over a factor of 6.…”
Section: Introductionmentioning
confidence: 99%
“…As a possible addition, this work presents a recently developed Timepix3 Radiation Monitor setup, of which the suitability to be used in the scope of R2E radiation level monitoring activities at CERN is being assessed. Timepix detectors have been successfully applied for the following wide range of activities: medical radiotherapy [9], high-resolution photon counting [10], radiation monitoring on the International Space Station [11], 3D colour X-ray [12], radiation imaging [13], luminosity measurements and radiation field characterization in the ATLAS detector [14].…”
Section: Introductionmentioning
confidence: 99%