2021
DOI: 10.1016/j.conbuildmat.2020.121115
|View full text |Cite
|
Sign up to set email alerts
|

Study of the characteristics of ballast bed resistance for different temperature and humidity conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(16 citation statements)
references
References 19 publications
1
15
0
Order By: Relevance
“…Ballast resistance R is a key factor with perceptible effect on the quality of signaling transmission, representing the degree of leakage between the rail and earth, susceptible to the conductivity degree of the track-bed, the material quality and the number of the sleeper, and the environmental temperature, humidity, and other factors. 37 We focus on two most unfavorable conditions: under too small R, the leakage of signal current between the rails will significantly increase, possibly causing the track circuit to incorrectly represent occupation, thereby affecting the operating efficiency; on the contrary, excessive R will deteriorate the shunting effect, may wrongly generate an upgrade signal. Therefore, the value of R is also critical to the return-current.…”
Section: Distribution Proportion Of Return-currentmentioning
confidence: 99%
“…Ballast resistance R is a key factor with perceptible effect on the quality of signaling transmission, representing the degree of leakage between the rail and earth, susceptible to the conductivity degree of the track-bed, the material quality and the number of the sleeper, and the environmental temperature, humidity, and other factors. 37 We focus on two most unfavorable conditions: under too small R, the leakage of signal current between the rails will significantly increase, possibly causing the track circuit to incorrectly represent occupation, thereby affecting the operating efficiency; on the contrary, excessive R will deteriorate the shunting effect, may wrongly generate an upgrade signal. Therefore, the value of R is also critical to the return-current.…”
Section: Distribution Proportion Of Return-currentmentioning
confidence: 99%
“…38 And the setting of the ambient temperature in the chamber was maintained for 36 h before relevant tests were performed in order to ensure that the internal temperature of the ballast met the requirements. 31 Influence of the temperature and the moisture level on the AOR of the ballast Five groups of tests were conducted on the AOR of the ballast for each condition. The test results are shown in Table 1.…”
Section: Laboratory Tests Of Ballast Aormentioning
confidence: 99%
“…38 And the setting of the ambient temperature in the chamber was maintained for 36 h before relevant tests were performed in order to ensure that the internal temperature of the ballast met the requirements. 31…”
Section: Laboratory Experiments Of the Ballast Aormentioning
confidence: 99%
See 1 more Smart Citation
“…This phenomenon can negatively affect the behavior of ballasted structures. Liu et al (2020a) performed a full-scale test of a ballasted railway track inside a test chamber in which the temperature and humidity was altered to find how changes in these parameters affect the ballast bed resistance. The authors concluded that the ballast bed resistance was lower in a dry, cold environment as compared to normal conditions.…”
Section: Climate Change Impact On Ballasted Railway Structuresmentioning
confidence: 99%