Study of the electric fields required for streamer propagation in humid air

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
33
0
1

Year Published

1995
1995
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(38 citation statements)
references
References 0 publications
4
33
0
1
Order By: Relevance
“…Following this assumption, the X‐ray source region's maximum charge is likely the maximum charge contained within the streamer zone. Furthermore, the electric field for streamer propagation is about 500 kV/m [ Allen and Boutlendj , ], which is greater than E th . Thus, finding the source region radius r 0 also determines the maximum possible streamer zone charge and so calculations were made to quantify the maximum electric charge of the streamer zone.…”
Section: Discussion Regarding the Maximum Charge Of The Streamer Zonementioning
confidence: 98%
“…Following this assumption, the X‐ray source region's maximum charge is likely the maximum charge contained within the streamer zone. Furthermore, the electric field for streamer propagation is about 500 kV/m [ Allen and Boutlendj , ], which is greater than E th . Thus, finding the source region radius r 0 also determines the maximum possible streamer zone charge and so calculations were made to quantify the maximum electric charge of the streamer zone.…”
Section: Discussion Regarding the Maximum Charge Of The Streamer Zonementioning
confidence: 98%
“…The performance of ESPs is affected by the characteristics of negative corona discharge. Corona discharge is a gas discharge phenomenon and it is influenced by many factors, including humidity and temperature [5][6][7]. Extensive research has been done to understand the effect of humidity and temperature on the corona discharge and the electric characteristics of ESPs.…”
Section: Introductionmentioning
confidence: 99%
“…The corona inception voltage decreased with the increase of relative humidity [6][7][8][9]. Peek proposed a formula to evaluate the corona inception electric field on conductors [10].…”
Section: Introductionmentioning
confidence: 99%
“…The subject of the last category is generally on the effect of atmospheric parameters variation on the breakdown voltage in rod-plane gaps [18] [22][23] [28] [33][34][35][36][37][38][39]. All these studies have demonstrated that the IEC correction method [20] has many setbacks and can not be globally applied to all electrode configurations and voltage shapes.…”
mentioning
confidence: 99%
“…A great majority of these researches have been conducted on medium and/or long air gaps 30 cm-400 cm using DC or Impulse voltages. There are few researches carried out on the effect of humidity in a couple of occasions on 20 cm air-gap showing that there is a large difference between threshold and stability fields for the smaller air gaps [37]. It has been recommended that in the short air gaps (dáO cm) the threshold field for streamer propagation in the steady voltage conditions is a good measure to find a factor to replace g in equation (2.21) formula in IEC method, for corona inception voltage [37].…”
mentioning