in 1984 and started a new life in 1988. At the end of 2017, the ion source was severely damaged. Several power supplies were destroyed. In this article we describe the process of restoring the VDG terminal. A number of power supplies were redesigned, built, tested and mounted in the Terminal. As a result of the work carried out during most of 2019, the VDG accelerator is now operational and we show data from the Rutherford Backscattering (RBS) analysis of a platinum coated silicon slab using the first proton and 𝛼 beams. Electronic diagrams of all supplies in their new configuration are provided for the benefit of this kind of RF-Ion sources users still numerous.
K: Accelerator Subsystems and Technologies; Ion sources (positive ions, negative ions, electron cyclotron resonance (ECR), electron beam (EBIS)); Instrumentation for particle accelerators and storage rings -low energy (linear accelerators, cyclotrons, electrostatic accelerators)