2012 IEEE PES Innovative Smart Grid Technologies (ISGT) 2012
DOI: 10.1109/isgt.2012.6175773
|View full text |Cite
|
Sign up to set email alerts
|

Study of unified control of STATCOM to resolve the Power quality issues of a grid-connected three phase PV system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…) Accordingly, the PWM reference voltages (Vref_a, Vref_b, Vref_c) of PV-STATCOM setup are attained by the reverse d-q transformation as specified in (5).…”
Section: Statcom Controllermentioning
confidence: 99%
See 2 more Smart Citations
“…) Accordingly, the PWM reference voltages (Vref_a, Vref_b, Vref_c) of PV-STATCOM setup are attained by the reverse d-q transformation as specified in (5).…”
Section: Statcom Controllermentioning
confidence: 99%
“…In addition, peak power output of SPV is hardly available for most of the time even when Sun shines brightly. For proper utilization of the PCS capacity, combining PV and STATCOM have been suggested in numerous research papers [1,2,[11][12][13][14][3][4][5][6][7][8][9][10]. These small rating units of PV generation is near to consumers such as roof-mounted mode contribute significantly to the overall generation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…STATCOM connected at distribution line works as active power filters by reducing harmonics and by improving power factor. By connecting renewable energy sources like PV at DC side of the compensator, required amount of reactive power can be injected or absorbed [3].…”
Section: ░ 1 Introductionmentioning
confidence: 99%
“…Similarly, in several studies, PV inverters operated as STATCOMs during daytime to provide the reactive power compensation in a distribution utility network [50,51]. However, the performance of the system depends on the rated capacity of the inverter, the constant DC-link voltage, and the maximum power point (MPP) instant time tracking in the distribution utility network [52]. In the study of [53], a PV-STATCOM was adopted with active power filtering against power quality issues in the PV system, such as transient voltages, voltage flickering, and harmonics.…”
Section: Multilevel Pv-statcom Applications In Grid-connected Systemsmentioning
confidence: 99%