Abstract: For the development of ACFM intelligent and visualization inspection system, based on a large number of finite element simulation results about ACFM crack angle detection, the calculate method of ACFM crack direction by 1-D array probe is present, and the experimental test is designed and conducted with the real crack. Test results show that, when tested by the 1-D probe composed of 4 couples of detecting coils, the accuracy of crack angle is more than 80%, which can meet the engineering needs, and the ACFM cr… Show more