Study on Compensation of Short Term Power Fluctuation by Use of Heat Pump Air Conditioning System based on Real Machine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 2 publications
0
11
0
Order By: Relevance
“…The green line shows the characteristic of the rate of change when "load up" signal is given to HPACS and the blue line shows the characteristic when "load down" signal is given. This characteristic of the rate of change was obtained by experiments that was conducted in previous study [13]. In the control system, the GE, the ESS, and the HPACS are controlled to keep the tie line power flow to its reference value.…”
Section: Power Fluctuation Compensation Reference Signalmentioning
confidence: 90%
See 1 more Smart Citation
“…The green line shows the characteristic of the rate of change when "load up" signal is given to HPACS and the blue line shows the characteristic when "load down" signal is given. This characteristic of the rate of change was obtained by experiments that was conducted in previous study [13]. In the control system, the GE, the ESS, and the HPACS are controlled to keep the tie line power flow to its reference value.…”
Section: Power Fluctuation Compensation Reference Signalmentioning
confidence: 90%
“…The power fluctuation compensation signal ΔP ref comp that is given to the HPACS is calculated by a microgrid control simulation in a previous study [13]. In the simulation, a microgrid model with a gas engine (GE), an ESS, a HPACS, and loads is assumed.…”
Section: Power Fluctuation Compensation Reference Signalmentioning
confidence: 99%
“…A technique that supports high‐speed ADR is called FastADR, and its future application is considered for high‐speed power supply–demand control services that response within several minutes after issuing a request …”
Section: Introductionmentioning
confidence: 99%
“…3 A technique that supports high-speed ADR is called Fas-tADR, and its future application is considered for high-speed power supply-demand control services that response within several minutes after issuing a request. [4][5][6][7][8][9] One of FastADR elements is a service provider called aggregator. Aggregator is a service provider that makes possible aggregation (request distribution and result acquisition) of FastADR power suppression values of multiple customer facilities.…”
Section: Introductionmentioning
confidence: 99%
“…As regards target loads for FastADR, building airconditioning (AC) facilities are considered as a promising candidate because of its large capacity and control flexibility [3][4][5][6][7][8][9]. However, it is required to predict actual power limitation response in real time in order to aggregate FastADR limitation amount across hundreds of buildings within a time as short as several minutes.…”
Section: Introductionmentioning
confidence: 99%