2017
DOI: 10.1016/j.nucengdes.2017.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Study on gas-liquid two-phase all-characteristics of CAP1400 nuclear main pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…Given the large size of the prototype pump and the high cost of the test using the prototype pump, models and test-stands with different scaling factors are commonly used (Cheng et al, 2016;Claus et al, 2005;Lu et al, 2017;Ni et al, 2017). Therefore, in this paper, a halfdimension scale model of an HPR1000 RCP was chosen, with the time cost required to build the computational domain and calculations reduced by approximately 30%.…”
Section: The Model Pumpmentioning
confidence: 99%
“…Given the large size of the prototype pump and the high cost of the test using the prototype pump, models and test-stands with different scaling factors are commonly used (Cheng et al, 2016;Claus et al, 2005;Lu et al, 2017;Ni et al, 2017). Therefore, in this paper, a halfdimension scale model of an HPR1000 RCP was chosen, with the time cost required to build the computational domain and calculations reduced by approximately 30%.…”
Section: The Model Pumpmentioning
confidence: 99%
“…The distinguishing feature of this software is that it is a three-dimensional design software based on inverse design methods. Many researchers in inverse design optimization have used this software, indicating that it has comprehensive and convenient functionality in inverse design [15].…”
Section: Introductionmentioning
confidence: 99%
“…(2014) studied the pressure pulsation characteristics of the reactor coolant pump at low flow conditions, and found that the unstable pressure pulsation in the small flow condition was caused by the backflow in the impeller vane flow runner, and that the backflow mainly exists in the impeller and vane blade import and export. Lu et al. (2017, 2018, 2019) studied the third and fourth generation nuclear main pumps, including gas–liquid two-phase flow and structural optimizationand finding in different gas fraction conditions, the homogeneous distribution of gas phase component in the fluid area was mainly related to the operating condition of pump, and when the volume flow rate deviates from the designed operating point, the fluid medium s gas phase and liquid phase will separate to some extent.…”
Section: Introductionmentioning
confidence: 99%